INSTALLATION AND CONFIGURATION
2-32
Document No.: COM-00-05-16 June 2006, Revised June 2014
Version: C.1
The following shows the DHCP Client screen.
Figure 2-41. DHCP Client
2.6.17
WAG Circuit ID
Every WAG that is operating as a gateway to the office must have a unique Circuit ID. The Circuit
ID is used by the office to know which WAG on the Ethernet LAN ATCS messages should be
routed to in order to reach type 7 devices that the WAG is connected to.
The WAG Circuit ID consists of three data fields and defaults to 000.0.00 (Disabled).
To Change the WAG Circuit ID:
1.
On the Second Configuration Menu, select “WAG Circuit ID” to be changed. The Change WAG
Routing Region screen appears.
Figure 2-42. Change WAG Routing Region Screen – Initial Screen
2.
From this initial screen (Figure 2-42), do one of the following:
a.
To leave the three digits of the first field of a currently assigned WAG Circuit ID
unchanged, press
ENTER
. Go to step 3.
b.
To change the three digits of the first field of the WAG Circuit ID, type the digits and then
press
ENTER
. Entry can be any value from 1 to 999. Go to step 3.
c.
To disable the WAG Circuit ID and set it to the default value, enter 0 (zero) and then press
ENTER
. The user is returned to the Second Configuration Menu.
3.
From the screen in figure 2-43, do one of the following:
a.
To leave the digit of the second field of a currently assigned WAG Circuit ID unchanged,
press
ENTER
. Go to step 4.