INSTALLATION AND CONFIGURATION
2-7
Document No.: COM-00-05-16 June 2006, Revised June 2014
Version: C.1
The addition of number 7, Run Executive internal clocks, RS232, Command Mode allows for
the WAG’s serial interface to be configured to utilize external transmit clocks or external
receive clocks, and for the WAG’s serial interface to be configured for the HDLC-UI mode. This
allows the operator to launch the WAG executive to use internal clocking in RS232 format into
the Command Mode. If the WAG is configured for external clocks and/or HDLC mode, the
operator may plug a laptop into the WAG, cycle power on the WAG, and tell the WAG that the
executive should ignore the configuration options and execute with internal clocks, in RS232
mode, and in Command Mode.
Figure 2-6. WAG Terminal Emulation Boot With Number 7 Screen
After 5 seconds and without the operator selecting a menu option, Figure 2-5 is replaced with the
screen in figure 2-7.
NOTE
If the screen shown in figure 2-7 does not appear and the statement “Boot
Monitor complete. Running WAG Executive.” appears at the bottom of figure 2-5;
the WAG is not in command mode. Wait at least 3 seconds and then type +++
and wait 3 seconds for the system to go to command mode (see paragraph
3.15).
NOTE
The following screen captures depict the WAG default settings. Actual results
reported may be different.