Dimensions and Connections
Figure 6 7XT7100-0BA00 Housing for panel surface mounting with terminals at both sides
Connections
for earthing
Recommended space to the
next unit
Dimensions in mm
View A
Current connections (terminals 1 to 6):
not used in 7XT71
Voltage connections (terminals 7 to 31):
isolated ring cable lug:
for bolts 4 mm diameter
max. major diameter 9 mm
type: e.g. PIDG of Messrs.
Tyco Electronics AMP
for copper wires with cross-section
1.0 mm
2
to 2.6 mm
2
AWG 17 to 13
solid bare copper wire directly:
cross-section 0.5 mm2 to 2.6 mm2
AWG 20 to 13
flexible wire requires end sleeves
max. torque value:
1.8 Nm or 16 in-lbs