7SR181 Solkor Technical Manual
Chapter 4 - Page 62 of 80
© 2016 Siemens Protection Devices Limited
Counters
Static (Steady-State) Object Number: 20
Change Event Object Number: 22
Static Variation reported when variation 0 requested: 1 (32-Bit Counter with Flag)
or 2 (16-Bit Counter with Flag)
or 5 (32-Bit Counter w/o Flag)
or 6 (16-Bit Counter w/o Flag)
Change Event Variation reported when variation 0 requested: 1 (32-Bit Counter Event with Flag)
or 2 (16-Bit Counter Event with Flag)
or 5 (32-Bit Counter Event with Flag and Time)
or 6 (16-Bit Counter Event with Flag and Time)
Frozen Counters
Static (Steady-State) Object Number: 21
Change Event Object Number: 23
Static Variation reported when variation 0 requested: 1 (32-Bit Frozen Counter with Flag)
or 2 (16-Bit Frozen Counter with Flag)
or 5 (32-Bit Frozen Counter with Flag and Time)
or 6 (16-Bit Frozen Counter with Flag and Time)
or 9 (32-Bit Frozen Counter w/o Flag)
or 10 (16-Bit Frozen Counter w/o Flag)
Change Event Variation reported when variation 0 requested: 1 (32-Bit Frozen Counter Event with Flag)
or 2 (16-Bit Frozen Counter Event with Flag)
or 5 (32-Bit Frozen Counter Event with Flag and Time)
or 6 (16-Bit Frozen Counter Event with Flag and Time)
Counter
Frozen Counter
Point
Index
Description
Default
Change
Event
Assigned
Class
(1, 2, 3
or none)
Default
Variation
Static
Object 20
Default
Variation
Event
Object 22
Deadband
Is Resettable
IsFreezable
Default
Change
Event
Assigned
Class
(1, 2, 3
or none)
Default
Variation
Static
Object 21
Default
Variation
Event
Object 23
0 Waveform Records
0,3
5
1
1
✔
0,2
9
1
1 Fault Records
0,3
5
1
1
✔
0,2
9
1
2 Event Records
0,3
5
1
1
✔
0,2
9
1
3 Data Log Records
0,3
5
1
1
✔
0,2
9
1
5 StartCount
0,3
5
1
1
✔ ✔
0,2
9
1
6 Start Count Target
0,3
5
1
1
✔
0,2
9
1
7 Active Setting Group
0,3
5
1
1
✔
0,2
9
1
11 CB Total Trip Count
0,3
5
1
1
✔ ✔
0,2
9
1
12 CB Ph A Trip Count
0,3
5
1
1
✔ ✔
0,2
9
1
13 CB Ph B Trip Count
0,3
5
1
1
✔ ✔
0,2
9
1
14 CB Ph C Trip Count
0,3
5
1
1
✔ ✔
0,2
9
1
15 CB E/F Trip Count
0,3
5
1
1
✔ ✔
0,2
9
1
16 CB Delta Trip Count
0,3
5
1
1
✔ ✔
0,2
9
1
17 CB Count To AR Block
0,3
5
1
1
✔ ✔
0,2
9
1
18 CB Frequent Ops Count
0,3
5
1
1
✔ ✔
0,2
9
1
21 E1 Counter
0,3
5
1
1
✔
0,2
9
1
22 E2 Counter
0,3
5
1
1
✔
0,2
9
1
23 E3 Counter
0,3
5
1
1
✔
0,2
9
1
24 E4 Counter
0,3
5
1
1
✔
0,2
9
1
5.3.5 Analog Inputs
The following table lists Analog Inputs (Object 30). It is important to note that 16-bit and 32-bit variations of Analog
Inputs, Analog Output Control Blocks, and Analog Output Statuses are transmitted through DNP as signed numbers.
Summary of Contents for 7SR18 Solkor
Page 1: ...Energy Management 7SR18 Solkor Line Differential Relay Reyrolle Protection Devices ...
Page 2: ...Siemens Protection Devices Limited 2 ...
Page 93: ...7SR18 Configuration Guide Unrestricted Page 12 of 12 2015 Siemens Protection Devices Limited ...
Page 221: ...7SR181 Solkor Technical Manual Chapter 4 Page 2 of 80 2016 Siemens Protection Devices Limited ...
Page 225: ...7SR181 Solkor Technical Manual Chapter 4 Page 6 of 80 2016 Siemens Protection Devices Limited ...