UMSITRPDS3-1
Installation
November 2010
4-25
3.
Thread ½" nipples, 3 inches (or less) in length, into the high- and low-pressure ports of the orifice
flanges. Thread sealant must be used.
4.
Thread the process connection blocks directly onto the nipples. Thread sealant must be used. The 1/2
NPT tapped hole in a process connection block is off center to accommodate 2-inch or 2.25-inch
centers. For 2.13" pipe centers, the tapped holes should be offset to the right side.
5.
Place the supplied Teflon gaskets on the connection blocks and bolt them to the manifold. Tighten the
mounting bolts according to the manifold manufacturer’s recommendations.
6.
Rotate the enclosure or reposition the optional display as necessary. Refer to Section 4.5.
4.4.3 Flange Mounting, Model 7MF4633/7MF4812
A liquid level transmitter can be flange mounted directly to the point of measurement on a vessel. The
flange-mounted diaphragm is factory assembled to the high-pressure side of the transmitter measuring
cell.
Figure 9-5 shows a typical flanged level transmitter. Table 4-2 includes the following mounting
information:
•
Flange thickness
•
Flange diameter and pressure rating
•
Number of flange mounting holes
•
Flange mounting hole diameter
•
Flange bolt circle diameter
Refer to Figure 9-5 and Table 4-2 when performing the following procedure:
1.
Determine needed bolt length. The user must supply mounting bolts, nuts, and washers. Bolt length is
determined by the combined thickness of the flange mounted on the vessel and the transmitter’s
flange.
2.
As necessary, loosen the enclosure rotation set screw and rotate the enclosure for clearance and best
viewing of the optional display.
3.
Bolt the transmitter’s flange to the vessel’s flange. Four mounting positions (90° increments) are
possible with 2-inch flanges and eight positions (45° increments) are possible with 4-inch flanges.
4.
Rotate the enclosure or reposition the optional display as necessary. Refer to Section 4.5.
Summary of Contents for 7MF4033 series
Page 48: ...Model 275 Universal Hart Communicator UMSITRPDS3 1 November 2010 2 26 ...
Page 86: ...Installation UMSITRPDS3 1 November 2010 4 34 ...
Page 152: ...Calibration and Maintenance UMSITRPSD3 1 November 2010 7 20 ...
Page 158: ...Circuit Description UMSITRPDS3 1 November 2010 8 6 ...
Page 197: ......
Page 198: ......
Page 200: ...Model Designations and Specifications UMSITRPDS3 1 November 2010 9 42 ...
Page 204: ...Glossary UMSITRPDS3 1 November 2010 10 4 ...
Page 208: ...Appendix A Online Configuration Map UMSITRPDS3 1 11 4 November 2010 ...
Page 216: ...Appendix C Elevation and Suppression Correction UMSITRPDS3 1 13 4 November 2010 ...