8.2
Cable data
Description
Cable for standard electrode or coil
Electrode cable, double shielded
Cable kit with standard coil cable and electrode cable double
shielded (also available as low noise cable for MAG 1100 sensor)
Standard applications
Table 8-6
Technical data, standard application cables
Coil cable
Standard electrode
cable
Basic data
No. of conductors
2
3
Min. sqr. area
0.5 mm
2
0.2 mm
2
Shield
Yes
Yes
Max. capacitance
N/A
350 pF/m
Max. cable loop resistance
Media temperature:
< 100 °C (212 °F)
40 Ω
N/A
> 200 °C (392 °F)
6 Ω
N/A
Cable glands on sensor and
transmitter
M20x1.5 gland - Cable ø 5 to 13 mm (0.20 to 0.51 inches)
½ NPT gland - cable ø 5 to 9 mm (0.20 to 0.35 inches)
Special applications, for example low conductivity or electrical noise
Table 8-7
Technical data, special application cables
Coil cable
Special electrode cable
Basic data
No. of conductors
3
3
Sqr. area
1.5 mm
2
0.25 mm
2
Shield
Yes
Double
Color code
Brown, blue, black
Brown, blue, black
Outside color
Grey
Grey
Ext. diameter
7.8 mm
8.1 mm
Conductor
Flexible CU
Flexible CU
Isolation material
PVC
PVC
Ambient temperature
Flexible installation
-5 to +70°C
(23 to 158°F)
-5 to +70°C
(23 to 158°F)
Non-flexible installtaion
-30 to +70°C
(-22 to 158°F)
-30 to +70°C
(-22 to 158°F)
Technical data
8.2 Cable data
SITRANS FM MAG 5100 W
Operating Instructions, 01/2020, A5E03063678-AC
53