
Connecting
5.2 Sensor Wiring
FUP1010 IP67 Portable
38
Operating Instructions, 03/2012, A5E02951522-02
4.
Pre-programmed Pipe Size and relevant pipe parameters will appear in menu cells. Press
<Right Arrow> and scroll to desired pipe size. Press <ENTER>. Enter dimensions
manually if pre-programmed dimensions do not match application.
Note
The DN sizes listed in the [Select Pipe Size] menu option list are referenced to DIN Table
2448. After selecting pipe size, check pipe OD and wall thickness for correct dimensions.
5.
Press the <Left Arrow> and return to the main menu.
Select a Liquid Class
1.
Press the <Down Arrow> and scroll to [Application Data].
2.
Press the <Right Arrow> to select [Liquid Class].
3.
Press the <Right Arrow> again and scroll to desired liquid.
4.
Press <ENTER> to save selection.
6HOHFW/LTXLG&ODVVIURP/LTXLG7DEOH
/LTXLG&ODVV
:DWHU&)
/LTXLG7DEOH
7DEOH$FWLYH
7HPS5DQJH)WR)
3LSH&RQILJ)XOO\'HYHORSHG
$QRPDO\'LDPV
$SSOLFDWLRQ'DWD
6LHPHQV'XDO3DWK>@$%&
①
Select from list.
Select Pipe Configuration
1.
Scroll down to [Pipe Config] and press the <Right Arrow>.
2.
Select a configuration that approximates the conditions upstream of your sensor
mounting location. (Refer to the definitions below.)
3.
Press <ENTER> to save selection.
Summary of Contents for 7ME3510
Page 2: ......
Page 10: ...Table of contents FUP1010 IP67 Portable 8 Operating Instructions 03 2012 A5E02951522 02 ...
Page 159: ...1010WP 7 21614 C ...
Page 160: ...1010WP 7 21614 C ...
Page 161: ...1010WDP 7 21614 C ...
Page 162: ...1010WDP 7 21614 C ...
Page 163: ......
Page 164: ......
Page 165: ......
Page 167: ...1012FP 8 DIRECT MODE REFLECT MODE INSTALLED ON PIPE 21614 C ...
Page 168: ......
Page 169: ...21614 C ...
Page 170: ......
Page 171: ......
Page 172: ......
Page 173: ......
Page 174: ...21614 C ...
Page 175: ...21614 C ...
Page 176: ...21614 C ...
Page 177: ...21614 C ...
Page 178: ...21614 C ...
Page 179: ...21614 C ...
Page 180: ...21614 C ...
Page 181: ......
Page 182: ......
Page 183: ...21614 C ...
Page 184: ...21614 C ...
Page 185: ...1012TP S 8 OUTLINE DIMENSIONS REFLECT MODE DIRECT MODE 1012TP S SERIES 21614 C MOUNTING TRACK ...
Page 186: ...REFLECT MODE DIRECT MODE 21614 C ...
Page 187: ...1015BC 1 8 21614 C ...
Page 188: ...21614 C INPUT OUTPUT TERMINALS 1015WP T10 8 ...
Page 189: ...21614 C INPUT OUTPUT TERMINALS 1015WP T26 8 ...
Page 190: ......
Page 191: ......
Page 192: ......
Page 193: ......
Page 195: ...DUAL HEAD CONFIGURATION 21614 C IN LINE CONFIGURATION FLOW ...
Page 196: ......
Page 197: ......
Page 208: ...Glossary FUP1010 IP67 Portable 162 Operating Instructions 03 2012 A5E02951522 02 ...
Page 212: ...Index FUP1010 IP67 Portable 166 Operating Instructions 03 2012 A5E02951522 02 ...
Page 213: ......