6.7.1.1
Val. uncertain
Error filter limit value uncertain (%)
for the average quality of the ultra‐
sonic measurement (signal pairs of
up and down). Below this value the
error status is set to uncertain and the
warning is indicated (on display and
output). The actual (maybe unstable)
measured values are displayed
Depends on system
configuration order‐
ing, for example 50%
for 2-path sensor sys‐
tem
1 %, 5 %, 10 %, 25 %,
50 %, 75 %, 90 %, 95
%, 99 %
Write
6.7.1.2
Value bad
Error filter value bad (%) with same
function as descripted above. Addi‐
tionally, the measured values are set
to "0" in the display and the output
signal to the error signal level
50 %
1 %, 5 %, 10 %, 25 %,
50 %, 75, %, 90 %, 95
%, 99 %, never
Write
D.1.7
Menu 7 - Sensor parameters
Menu
code
Device function,
Parameters
Description
Factory setting
Setting options
Read
or write
7.1
Sensor calib
7.1.1
Calib choice
Calibration choice
AUTO (SONOKIT sys‐
tems)
WET (SONO 3100
and SONO 3300 sys‐
tems)
WET
AUTO
Write
7.1.2
App. param.
Application parameters
7.1.2.1
Viscosity
Viscosity of media
(viscosity for water at 20 °C is 0.01
cm
2
/s)
0.01 cm
2
/s
0.005 to 5 cm
2
/s
(optional unit: in
2
/s)
Write
7.1.2.2
Correct. fact.
Calibration factor compensation val‐
ue for flow sensor to correct the
measured values; typical 1.0
1.0
0.000001 to 100
Write
7.1.2.3
Fl. offset comp.
Offset compensation value for flow
sensor (in flow unit) (in the menu
3.1.1 closed unit)
+0.00000 m
3
/h
-max. flow to
+max.flow
(see menu 3.1.2)
Write
7.1.2.4
Cable len. TOFKOR Total cable length for a path.
All paths must have the same length
Depending on selec‐
tion (factory setting
with the ordered
transducer cable
length)
0 to 500 m
Write
7.1.3
Pipe geometry
7.1.3.1
Pipe diameter
7.1.3.1.
1
Engr.unit
Unit selection (m or in)
m
m
in
Write
7.1.3.1.
2
Pipe diameter
Inside diameter of pipe (m or in)
Depending on selec‐
tion at ordering
0.01 to 4.0 m
Write
7.1.3.2
Roughness
HMI menu structure
D.1 Menu items (FW Rev. 4.00.00)
SITRANS FUS060 with PROFIBUS PA
116