6.2 Interface overview
6-150
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
6.2.2
5 kW UI module interface overview
Table 6-2
Interface overview, 5 kW UI modules
Term.
No.
Desig-
nation
Function
Type
1)
Typ. voltage/limit values
Max. cross–section
6)
U1
V1
W1
X1
Line supply connection
I
3–ph. 400 V AC
4 mm
2
finely–stranded
without conductor end
sleeves
6 mm
2
with pin–type
cable lug
PE
–
X131
X351
Protective conductor
Electronics M
Equipment bus
Grounding bar
3)
I
I
I/O
I/O
0 V
0 V
Various
–300 V
M5 thread
M4 thread
34–core ribbon cable
Busbar
P600
M600
DC link
I/O
+300 V
–300 V
Conductor bar
M500
P500
1U1
2U1
1V1
2V1
1W1
2W1
X181
X181
X181
X181
X181
X181
X181
X181
DC link power supply
DC link power supply
Output L1
Input L1
Output L2
Input L2
Output L3
Input L3
I
I
O
I
O
I
O
I
–300 V
+300 V
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
3–ph. 400 V AC
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
5.3
5.2
5.1
nc
X121A
X121A
X121A
X121A
Relay contact
Group signal
I
2
t/motor temperature
NC
NO
I
1–ph. 50 V DC/0.5 A/12 VA max
1–ph. 5 V DC/3 mA min
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
74
73.2
73.1
72
X121B
X121B
X121B
X121B
Relay signal
Ready/
fault
NC
I
I
NO
1–ph.250 V AC/50 V DC/2 A max
7)
5 V DC/3 mA min
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
63
2)
9
2)4)
9
2)4)
64
2)
R
5)
19
X141AX
141A
X141A
X141A
X141A
X141A
Pulse enable
FR+
FR+
Drive enable
RESET
FR–, reference ground enable
voltage
I
O
O
I
I
O
+13 V...30 V/R
E
= 1.5 k
Ω
+24 V
+24 V
+13 V...30 V/R
E
= 1.5 k
Ω
terminal 19/R
E
= 10 k
Ω
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1) I = input; O = output; NC = NC contact; NO = NO contact
2) Term. 19 is the reference ground (connected through 10 k
W
to the general reference ground X131 inside the module)
Terminal 15 must not be connected to PE, to terminal 19 or to external voltage sources
Terminal 19 can be connected to X131.
The terminal may be used exclusively for enabling the associated drive group.
3) The grounding clip is used to ground the DC link M busbar through 100 k
Ω
(must be closed;
the grounding clip must be opened if the system is subject to a high–voltage test).
4) max. current load of terminal 9 – terminal 19
1 A
Notice: For the 5 kW, there are no terminals 7, 45, 44 and 10.
5) RESET = resets the fault memory, edge–triggered for the complete drive group
(terminal ”R”
Term. 19 = RESET)
6) For UL certification
:
only use copper cables dimensioned for an operating temperature
60
7) In accordance with EN 60204–1 (machine safety),
control transformers must be used for AC control voltages.
6 Infeed Modules
02.03
02.07
05.08