![Siemens 6GK5786-1FC00-0AA0 Operating Instructions Manual Download Page 62](http://html.mh-extra.com/html/siemens/6gk5786-1fc00-0aa0/6gk5786-1fc00-0aa0_operating-instructions-manual_380567062.webp)
Device variant W786-x RJ-45
Follow the steps below to connect an Ethernet cable to a SCALANCE W786 with an RJ-45 jack:
1. Insert the RJ-45 plug of the Ethernet cable in the jack of the SCALANCE W786-x RJ-45.
2. Secure the Ethernet cable with a strain relief clamp.
Note
Keep the dummy plugs
Keep any dummy plugs taken out of the slots for later use.
See also
Cables for power supply and Ethernet (Page 53)
6.7
SFP/SFP+ transceivers
Approved plug-in transceivers for SCALANCE W786-2 SFP
SFP/SFP+ plug-in transceivers allow the SCALANCE W786-2 SFP device to be equipped with
interfaces for fiber-optic cables. There are SFPs for different cable materials (multimode, single
mode) and cable lengths. The following table lists the models approved for SCALANCE W786-2
SFP.
Transceiver
Properties
Article number
SFP992-1
1 x 1000 Mbps, LC port optical, multimode
glass, up to max. 750 m
6GK5992-1AL00-8AA0
SFP992-1LD
1 x 1000 Mbps, LC port optical, single mode
glass, up to max. 10 km
6GK5992-1AM00-8AA0
SFP992-1LH
1 x 1000 Mbps, LC port optical, single mode
glass, up to max. 40 km
6GK5992-1AN00-8AA0
SFP992-1LH+
1 x 1000 Mbps, LC port optical, single mode
glass, up to max. 70 km
6GK5992-1AP00-8AA0
SFP992-1ELH
1 x 1000 Mbps, LC port optical, single mode
glass, up to max. 120 km
6GK5992-1AQ00-8AA0
Connecting up
6.7 SFP/SFP+ transceivers
SCALANCE W786-x
62
Operating Instructions, 12/2021, A5E03678337-14
Summary of Contents for 6GK5786-1FC00-0AA0
Page 8: ...Introduction SCALANCE W786 x 8 Operating Instructions 12 2021 A5E03678337 14 ...
Page 10: ...Safety notices SCALANCE W786 x 10 Operating Instructions 12 2021 A5E03678337 14 ...
Page 66: ...Maintenance and cleaning SCALANCE W786 x 66 Operating Instructions 12 2021 A5E03678337 14 ...
Page 82: ...Dimension drawings SCALANCE W786 x 82 Operating Instructions 12 2021 A5E03678337 14 ...