Connection
6.3 Ethernet
SCALANCE W1788-x / W1748-1
66
Operating Instructions, 03/2022, C79000-G8976-C484-05
6.3
Ethernet
For connection to Industrial Ethernet at 10/100/1000 Mbps, the devices have the
following two M12 interfaces: X-coded, 8-pin.
Position and pin assignment
①
M12 interface P1 LAN
②
M12 interface P2 LAN PoE
The power can also be supplied via this interface (Power over Ethernet).
The eight-pin connection socket has the following pin assignment:
Pin
Assignment
1
D0+
2
D0-
3
D1+
4
D1-
5
D3+
6
D3-
7
D2-
8
D2+
Connecting Ethernet ports
1.
Connect the plug and socket. Make sure that they lock in place correctly.
2.
Tighten the knurled screw (tightening torque 1 Nm).