*) Depending on the cable used:
• If you are using at least OM1 fibers (attenuation ≤ 1.5 dB/km, bandwidth length product ≥
500 MHz*km), you can reach a cable length of up to 3 km.
• When are using fibers with attenuation values ≤ 1 dB/km, you can reach a cable length of up
to 5 km.
You can find additional information in the "Industrial Ethernet / PROFINET Passive network
components" System Manual, see also section "Introduction", paragraph "Additional
documentation".
5.6.3.3
SFP991-1LD(C)
Properties
Transmission mode
100Base-LX complying with IEEE 802.3
Transmission rate
100 Mbps (Fast Ethernet)
Transmission medium
Single mode fiber-optic cable
Light source
Class1-LASER "Eye safe"
Wavelength
1310 nm
Cable length (max.) *
)
26 km
Transmitter output (optical)
Minimum
-15 dBm
Maximum
-8 dBm
Receiver input
Sensitivity min.
-28 dBm
Input power max.
-8 dBm
*
)
Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET
Passive network components" System Manual, see also section "Introduction", paragraph "Additional
documentation".
5.6.3.4
SFP992-1LD(C)
Properties
Transmission mode
1000Base-LX complying with IEEE 802.3
Transmission rate
1000 Mbps (Gigabit Ethernet)
Transmission medium
Single mode fiber-optic cable
Light source
Class1-LASER "Eye safe"
Wavelength
1310 nm
Cable length (max.) *
)
10 km
Transmitter output (optical)
Minimum
-9.5 dBm
Maximum
-3 dBm
Receiver input
Sensitivity min.
-19 dBm
Input power max.
-3 dBm
*
)
Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET
Passive network components" System Manual, see also section "Introduction", paragraph "Additional
documentation".
Device description
5.6 SCALANCE X204RNA EEC interfaces
SCALANCE X-200RNA
46