Archiving/MMI (MMI: Man Machine Interface)
In this group, you enter the address of a server to which you can send images and/or data records
for diagnostics.
Table 8-22
Archiving/MMI
Parameter
Possible values
Default
Description
IP address
xxx.xxx.xxx.xxx
192.168.0.45
IP address of the server for diagnostic information
Port
Device-specific
8765
Corresponding port of this server
Time limit
0 ... 3600
10
• 0: There is no transfer of cyclic monitoring frames to test
the connection between the camera and the server.
• Otherwise: Time in seconds after which a monitoring
frame is sent to test the connection between the cam‐
era and the server. If the server does not respond to this
frame within the monitoring time, an error is output
(only when the camera is in RUN or "Save program"
mode) and the connection is reestablished.
Remote client
xxx.xxx.xxx.xxx
0.0.0.0
IP address of the HTTP client that is permitted to execute
remote functions such as the remote XML command.
To deactivate the remote functions via this connection, en‐
ter "0.0.0.0".
Correlations and dependencies of the parameters
Table 8-23
Correlations and dependencies of the parameters
Parameter
Dependency
Description
PROFINET IO
IP mode
The parameters of the "PROFINET IO" group are only active
when the "PROFINET (FB79)" IP mode is selected.
Host name
PROFINET IO device name
The host name only corresponds to the "PROFINET IO de‐
vice name" when the "PROFINET (FB79)" IP mode is selec‐
ted.
PROFINET IO device
name
Host name
The "PROFINET IO device name" only corresponds to the
"Host name" when the "Manual" IP mode is selected.
Note
If the "PROFINET (FB79)" IP mode is not set, the "Device
name" corresponds to the "Host name".
8.4.1.2
Use
You define the signal and communication paths in this area. For example:
• The path signals must take to reach the camera
• The communication path that is used to output a modified result string
Parameterization
8.4 Settings
SIMOCRANE CenSOR
94
Operating Instructions, 07/2021
Summary of Contents for 6GA7202-2AA10-1BF1
Page 2: ......
Page 8: ...Table of contents SIMOCRANE CenSOR 6 Operating Instructions 07 2021 ...
Page 10: ...Introduction SIMOCRANE CenSOR 8 Operating Instructions 07 2021 ...
Page 62: ...Commissioning 7 3 Setting up the camera SIMOCRANE CenSOR 60 Operating Instructions 07 2021 ...
Page 158: ...Appendix A 3 Standards and certifications SIMOCRANE CenSOR 156 Operating Instructions 07 2021 ...
Page 168: ...Index SIMOCRANE CenSOR 166 Operating Instructions 07 2021 ...