Siemens Mobility Limited
Sopers Lane, Poole, Dorset
BH17 7ER
Version
11
Page 84 of 117
Status
Issued
Last Editor
Jeerh, Manpreet
Date
March 2020
Document
Name
WIMAG GENERAL HANDBOOK
Doc. No.
667/HB/47200/000
Copyright
©
Siemens Mobility Limited 2012. All Rights Reserved.
15
Commissioning
This section is used to outline the commissioning methodology for the WiMag Vehicle
Detection system.
15.1 Access Point Commissioning
The first step will be to confirm that the access point is operating as expected. The
following steps should be performed on each access point;
1.
Connect to the access point using the ‘Traffic Dot 2.0’ application
2. Enable the map mode.
Figure 65 : Traffic Dot 2 Map Mode
3. Each detector should have been positioned on the map in its relative position.
4.
Confirm each detector ‘indication’ is a reflection of the sensor’s true status.
15.2 Standard interface Card/WiMag Loop Detector Replacement Card
Commissioning
The access points connect to one or more interface card. The following step should
ensure the interface card is receiving the detector information from the appropriate access
point;
1. Connect to the interface card
2.
Select the ‘Board Test’ page on the web interface