4.3
Function diagram for automatic mode
Requirements
• Start type: Manual start
• Protective door closed and signal present at P1 and P2
• Magnet of the tumbler provides positive checkback signal (signal to MAG)
• "AUTOMATIC MODE" is selected (no signal at EA1 and signal at EA2)
max n1
AUTO
min n2
STANDSTILL
n5
start
13/14 and 15
23/24 and 25
Start
override
Functions
4.3 Function diagram for automatic mode
3TK2810-1 safety-related speed monitor
Equipment Manual, 05/2020, NEB926246402000/RS-AE/007
35