background image

SIMATIC  ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0)  

______________
______________
______________
______________
______________

 

 

Preface 

 

 

Properties 

 

1

Parameters 

 

2

Diagnostics 

 

3

Analog value representation

 

4

Connecting 

 

5

SIMATIC  

ET 200S distributed I/O

2AO U HF analog electronic module 

(6ES7135-4LB02-0AB0)  

Manual 

04/2007 

A5E01076940-01 

 

Summary of Contents for 2AO U HF

Page 1: ...B0 ______________ ______________ ______________ ______________ ______________ Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation 4 Connecting 5 SIMATIC ET 200S distributed I O 2AO U HF analog electronic module 6ES7135 4LB02 0AB0 Manual 04 2007 A5E01076940 01 ...

Page 2: ...a device system may only be performed by qualified personnel Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission ground and label devices systems and circuits in accordance with established safety practices and standards Prescribed Usage Note the following WARNING This device may only be used for the applications de...

Page 3: ... describes the components that are valid at the time of publication Recycling and disposal Thanks to the fact that it is low in contaminants this ET 200S module is recyclable For environmentally compliant recycling and disposal of your electronic waste please contact a company certified for the disposal of electronic waste Additional support If you have any questions relating to the products descr...

Page 4: ... 5050 223 For more information about our technical support refer to our Web site at http www siemens de automation service Service Support on the Internet In addition to our documentation services you can also make use of our comprehensive online knowledge base on the Internet http www siemens com automation service support There you will find Our Newsletter which constantly provides you with the ...

Page 5: ...gnostics using LED display 13 3 2 Error types 14 4 Analog value representation 15 4 1 Introduction 15 4 2 Analog value representation for measuring range with SIMATIC S7 15 4 3 Output ranges 16 4 4 Effect on analog value representation 17 4 4 1 Effect of the supply voltage and the operating state on analog output values 17 4 4 2 Effect of the value range on the 2AO U HF analog output 18 5 Connecti...

Page 6: ...Table of contents 2AO U HF analog electronic module 6ES7135 4LB02 0AB0 6 Manual 04 2007 A5E01076940 01 ...

Page 7: ... cycle TDPmin 0 7 ms Minimum conversion time of the output modules TWAmin 0 5 ms Supports I M functions General terminal assignment Note Terminals A4 A8 A3 and A7 are only available on certain terminal modules Terminal assignment for 2AO U HF 6ES7135 4LB02 0AB0 Terminal Assignment Terminal Assignment Notes 1 QV0 5 QV1 2 S0 6 S1 3 Mana 7 Mana 4 S0 8 S1 A4 AUX1 A8 AUX1 A3 AUX1 A7 AUX1 QVn Analog out...

Page 8: ... 4LB02 0AB0 TM E15C26 A1 6ES7193 4CA50 0AA0 TM E15C24 01 6ES7193 4CB30 0AA0 Spring terminal TM E15S26 A1 6ES7193 4CA40 0AA0 TM E15S24 01 6ES7193 4CB20 0AA0 Screw type terminal TM E15N26 A1 6ES7193 4CA80 0AA0 TM E15N24 01 6ES7193 4CB70 0AA0 Fast Connect 8 6 49 6 0DQD 6 49 6 0DQD ZLUH ZLUH LULQJ H DPSOHV Block diagram 8 9 0 8 0 1 0 1 0 1 3 3 7b 6 DFNSODQH EXV LQWHUIDFH DFNSODQH EXV Figure 1 1 Block ...

Page 9: ...everse polarity protection Yes Electrical isolation Between the channels and backplane bus Yes Between the channels and load voltage L Yes Between the channels No Permissible potential difference Between MANA and the central grounding point Uiso 75 V DC 60 V AC Insulation tested 500 VDC Current consumption From load voltage L Max 80 mA Power dissipation of the module Max 1 2 W Status interrupts di...

Page 10: ...tages currents applied from outside Voltage at the outputs to MANA Max 15 V continuous 75 V for max 1 ms sampling ratio 1 20 Connection of actuators Voltage output 2 wire connection 4 wire connection Possible without compensation of the line resistances Possible I M functions The I M data can be read from the module using interface modules with the following order numbers or firmware product versi...

Page 11: ...alue Keep last value No output current or voltage Module Type range of output Deactivated 1 to 5 V 10 V 10 V Channel Substitute value 2 To 65 535 value range must lie within the nominal range 10 V 0 V 5 V 0 V 1 to 5 V 1 V Channel 1 No diagnostics detection between 0 296 V and 0 296 V 2 If there is no voltage being supplied to the interface module or COMPACT module but the supply to the analog outp...

Page 12: ...Parameters 2 1 Parameters 2AO U HF analog electronic module 6ES7135 4LB02 0AB0 12 Manual 04 2007 A5E01076940 01 ...

Page 13: ...3 1 Diagnostics using LED display LED display 1 6 Batch error red Status and error displays Event LED SF Cause Remedy On No configuration or incorrect module plugged in No load voltage present There is a diagnostic message Check the parameter assignment Check the load voltage Evaluate the diagnostics ...

Page 14: ...annel Inserted module does not match the one configured Incorrect parameter assignment Correct the configuration align actual and set configuration Correct the parameter assignment wire break diagnostics only parameterized for the permitted measuring ranges 9D 01001 Error Internal module error has occurred diagnostic message on channel 0 applies to the entire module Replace the module 1D 00001 Sho...

Page 15: ... controllers and similar 4 2 Analog value representation for measuring range with SIMATIC S7 Analog value representation With the same nominal range the digitized analog value is the same for input and output values Analog values are represented in two s complement The following table shows the analog value representation of the analog electronic modules Table 4 1 Analog value representation SIMAT...

Page 16: ...mat Units Analog value Resolution in bits Decimal Hexadecimal High byte Low byte 11 S 16 10H S 0 0 0 0 0 0 0 0 0 1 x x x x 12 S 8 8H S 0 0 0 0 0 0 0 0 0 0 1 x x x 13 S 4 4H S 0 0 0 0 0 0 0 0 0 0 0 1 x x 15 sign 1 1H S 0 0 0 0 0 0 0 0 0 0 0 0 0 1 4 3 Output ranges Voltage output ranges 5 V and 10 V Table 4 3 SIMATIC S7 format Output range 5 V and 10 V Output range 5 V Output range 10 V Units Range ...

Page 17: ...lues The output values of the analog modules are dependent on the supply voltage for electronics encoders and on the operating state of the PLC CPU of the DP master This is illustrated by the table below Table 4 5 Relationship between the analog output values for the operating state of the PLC CPU of the DP master and the supply voltage L Operating state of the PLC CPU of the DP master Supply volt...

Page 18: ...utputs depends on where the output values fall within the value range This is illustrated by the table below Table 4 6 Response of the analog modules depending on where the analog output value falls within the range of values Output value falls in Output value in SIMATIC S5 S7 format Nominal range Value from DP master Over underrange Value from DP master Overflow 0 signal Underflow 0 signal Prior ...

Page 19: ... signals This reduces the effect of interference You should ground the shield of the analog cables at both ends If there are differences in potential between the cable ends an equipotential bonding current that may interfere with the analog signals will flow across the shield In this case you should only ground the shield at one end of the cable Analog output modules In the case of the analog outp...

Page 20: ...Connecting 5 1 Connecting analog outputs 2AO U HF analog electronic module 6ES7135 4LB02 0AB0 20 Manual 04 2007 A5E01076940 01 ...

Page 21: ... Analog output modules in SIMATIC S7 format 16 B Basic knowledge requirements 3 C Cables for analog signals 19 D Disposal 3 I Internet Service Support 4 L LED display 13 M Measured value resolution 16 Measuring ranges with SIMATIC S7 15 O Output ranges 16 R Recycling 3 Response of the analog modules 17 During operation 17 When faults occur 17 S Scope Manual 3 Service Support 4 T Technical Support ...

Page 22: ...Index 2AO U HF analog electronic module 6ES7135 4LB02 0AB0 22 Manual 04 2007 A5E01076940 01 ...