![Siemens 1PQ8 Operating Instructions & Installation Instructions Download Page 105](http://html.mh-extra.com/html/siemens/1pq8/1pq8_operating-instructions-and-installation-instructions_378977105.webp)
9.2.4
Roller-contact bearings
9.2.4.1
Removing roller bearing
Preparation
● Remove any grease feeders, shock pulse measurement equipment and possibly mounted
instrumentation at the DE and NDE.
● Remove the coupling on the drive end or make the shaft extension freely accessible.
Note
For a schematic diagram of the respective component layout, see the chapter "Spare
Procedure
1. Remove the components of the bearing mounting.
– Dismount the outer bearing cover.
If present: Remove the V ring (Page 106).
Uninstall the labyrinth sealing ring (only for the option "Increased degree of
– Ensure that the inner bearing cover is no longer attached to the bearing housing or end
shield.
There may be springs in the inner bearing cover.
– Support the rotor for the uninstallation of bearing housing or end shield.
– If necessary, remove the bearing housing from the end shield.
– Remove the end shield. Dependent on shaft height, roller bearing type and design, it is
either a bearing head design or a bearing housing design.
– Remove the locking ring from the shaft or the set screw, depending on the version.
2. Pull off the roller bearing together with the grease slinger.
Maintenance
9.2 Corrective Maintenance
SIMOTICS TN Series N-compact 1LH8
Operating Instructions 06/2017
105
Summary of Contents for 1PQ8
Page 2: ...06 06 2017 10 16 V15 00 ...
Page 92: ...Operation 8 10 faults SIMOTICS TN Series N compact 1LH8 92 Operating Instructions 06 2017 ...
Page 130: ...Service and Support SIMOTICS TN Series N compact 1LH8 130 Operating Instructions 06 2017 ...
Page 134: ...Quality documents SIMOTICS TN Series N compact 1LH8 134 Operating Instructions 06 2017 ...
Page 139: ......