Supplementary devices
A temperature sensor is integrated in the stator winding to monitor the winding temperature.
The type of temperature sensor is specified on the rating plate.
Depending on the order options, various supplementary devices such as encoder systems can
be either installed or mounted.
Holding brake
Depending on the order, a special version of a holding brake from the Stromag company is
mounted. Various types of holding brake are mounted depending on the shaft height.
NOTICE
Technical data for the special version of the holding brake
The following technical data applies to the special version of the mounted holding brake. The
corresponding data in the manufacturers operating instructions do not apply.
Table 3-4
Technical data of the holding brake
Technical data
NFF-A 63
AH180
NFF-A 100
AH225
Braking torque
M
Brake
[Nm]
1000
1600
Max. speed
n
Brake
[rpm]
3500
3100
Weight incl. hollow shaft
m
brake
[kg]
63
88
Moment of inertia
J
brake
[kgm
2
]
0,022
0,051
Total moment of inertia (emer‐
gency stop)
J
total
[kgm
2
]
1,3
3,9
Rated voltage
U
[V]
230 V (AC)
230 V (AC)
Permitted single switched energy P
[W]
98
210
Coil current
I
[A]
2,21
2,70
Number of emergency stops
Z
-
2100
1200
Opening time
[ms]
300
300
Closing time
[ms]
80
100
Note
More information
● Magnetic field when the brake is open (Page 84)
See also
Operating instructions, holding brake (Page 139)
Description
SIMOTICS M-1PH8 1PH818., 1PH822.
26
Operating Instructions 07/2016
Summary of Contents for 1PH818
Page 2: ...18 07 2016 14 04 V14 00 ...
Page 12: ...Introduction SIMOTICS M 1PH8 1PH818 1PH822 12 Operating Instructions 07 2016 ...
Page 28: ...Description SIMOTICS M 1PH8 1PH818 1PH822 28 Operating Instructions 07 2016 ...
Page 100: ...Operation 8 10 Faults SIMOTICS M 1PH8 1PH818 1PH822 100 Operating Instructions 07 2016 ...
Page 136: ...Quality documents SIMOTICS M 1PH8 1PH818 1PH822 136 Operating Instructions 07 2016 ...
Page 197: ...AA Manual STROMAG Break AC Manual Ziehl Abegg external fan ...