![Siemens 1PH818 Operating Instructions & Installation Instructions Download Page 103](http://html.mh-extra.com/html/siemens/1ph818/1ph818_operating-instructions-and-installation-instructions_378974103.webp)
Immediately perform an inspection after such faults.
9.2.2
Initial inspection
Perform the following checks after approximately 500 operating hours or at the latest after six
months:
Table 9-1
Checks after installation or repair
Check
When the
motor is
running
At stand‐
still
The electrical parameters are maintained.
X
The smooth running characteristics and machine running noise have not
deteriorated.
X
The motor foundation has no cracks and indentations. (*)
X
X
(*) You can perform these checks while the motor is running or at a standstill.
Additional checks may also be required according to the system-specific conditions.
NOTICE
If you detect any deviations during the inspection, you must rectify them immediately. They
may otherwise damage the motor.
9.2.3
Main inspection
● While the motor is running, check that:
– The stated electrical characteristics are being observed
– The smooth running characteristics and machine running noise have not deteriorated
● Once the machine has been shut down, check that:
– The motor foundation has no indentations or cracks
– The machine is aligned within the permissible tolerance ranges
– All the fixing bolts/screws for the mechanical and electrical connections have been
securely tightened
– The winding insulation resistances are sufficiently high (Page 50)
– Any bearing insulation has been fitted as shown on plates and labeling.
– Cables and insulating parts and components are in good condition and there is no
evidence of discoloring
Maintenance
9.2 Inspection and maintenance
SIMOTICS M-1PH8 1PH818., 1PH822.
Operating Instructions 07/2016
103
Summary of Contents for 1PH818
Page 2: ...18 07 2016 14 04 V14 00 ...
Page 12: ...Introduction SIMOTICS M 1PH8 1PH818 1PH822 12 Operating Instructions 07 2016 ...
Page 28: ...Description SIMOTICS M 1PH8 1PH818 1PH822 28 Operating Instructions 07 2016 ...
Page 100: ...Operation 8 10 Faults SIMOTICS M 1PH8 1PH818 1PH822 100 Operating Instructions 07 2016 ...
Page 136: ...Quality documents SIMOTICS M 1PH8 1PH818 1PH822 136 Operating Instructions 07 2016 ...
Page 197: ...AA Manual STROMAG Break AC Manual Ziehl Abegg external fan ...