Coupled motors
10.3 Machine design and adjustment of the phase angle
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
281
Power connection
Table 10- 1 Power connection when two torque motors are operated in parallel
Motor Module
Master
Stoker
Tandem arrangement
Stoker
Janus arrangement
U2
U
U
U
V2
V
V
W
W2
W
W
V
10.3
Machine design and adjustment of the phase angle
Each rotation of the mounted rotor induces the 3-phase EMF of the motor in the stator phase
windings. When the master and stoker operate in parallel, the phase angle of each stoker
EMF must match the phase angle of the master EMF.
To adjust the phase angle, the stator and rotor have reference marks on their face sides.
The reference marks of the motors are shown in Chapter "Installation drawings/Dimension
●
The reference mark in the stator depends on the motor article number.
–
1FW6092-xxCxx-xxxx, 1FW6132-xxCxx-xxxx, and 1FW6152-xxCxx-xxxx:
center hole
–
1FW6192-xxCxx-xxxx and 1FW6232-xxCxx-xxxx:
notch
●
The reference mark in the rotor is a centering bore without thread.