Electrical connection
8.3 System integration
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
245
8.3
System integration
8.3.1
Drive system
Components
The drive system that feeds a motor comprises an infeed module, a power module and a
control module. For the SINAMICS S120 drive system, these modules are called "Line
Modules", "Motor Modules" and "Control Units". Line Modules can be regulated with
feedback (ALM, Active Line Module), unregulated with feedback (SLM, Smart Line Module),
or unregulated without feedback (BLM, Basic Line Module).
To operate several motors simultaneously on a single drive system, either one Motor Module
per motor or one Motor Module for several motors can be provided, depending on the
application. The appropriate choice of Line Module is primarily determined by the power
consumption of the motors used. Other important related factors are the line voltage,
regenerative feedback, and the DC-link voltage.
Note
Cables for power connection
The connecting cables required for the power connection depend on the current demand of
the motor being used.
The following diagram shows an example of a motor integrated into a system with the
connection of Temp-S, Temp-F and an absolute encoder (EnDat with 1 V
PP
, order
designation EnDat01 or EnDat02, or SSI with 1 V
PP
) via SME125.
Figure 8-3
System integration with SME125 (example)
Summary of Contents for 1FW6092-2PC15-6AB3
Page 1: ...1FW6 High Speed built in torque motors ...
Page 2: ......
Page 299: ......