IV352 Rev.02
Date Issue:
2012-10-27
Page 101 di 232 + FR
WARNING!
Please do not connect more than one PV inverter to one AC circuit breaker.
WARNING!
A circuit breaker shall be installed between the PV inverter and public grid. In the event an
individual circuit breaker is used for N wire, please do not disconnect N wire before
disconnecting L wire, otherwise the PV inverter might be damaged.
2.7. Connection of PV Array (DC)
"
Applicable Type of PV Array
The PV modules connected to one PV inverter must consist of PV array of the same type. The table
below lists the applicability of different type of PV array,
PV Array Type
Applicability
Mono-crystalline
Yes
Multi-crystalline
Yes
Thin-Film(Without earthed positive or negative pole)
Yes
Specific type with earthed positive pole
No
Specific type with earthed negative pole
No
Ⴃ
Table 2.7-1 Applicability of PV arrays
WARNING!
Please consult your PV array supplier and confirm the type of PV array and applicability
according the table above.
WARNING!
The PV modules connected to one PV inverter must be of the same type. Do not connect
one string to more than on PV inverter.
WARNING!
The PV array shall comply with IEC 61730 Class A rating
"
Electrical Limitations
#
The maximum open-circuited voltage (V
oc
) of each PV string shall not exceed the Maximum
Working Voltage Range as specified in the table below.
#
The short-circuited current (
I
sc
) of the PV string should not exceed the Inverter’s permitted
maximum DC current as specified below.