Introduction

Read these instructions completely before you use the 

multi-point locks.
To safely use the multi-point locks BS 2100 and 

BS 2800, adhere to the defined operating instructions 

in order to prevent functional disorders or damage. 

Follow the notes in Chapter 2 "Safety", in order to 

prevent personal injury or damage.

1.1 

Manufacturer and Service

KFV Karl Fliether GmbH & Co. KG 

 

A company of the SIEGENIA GROUP

 

Siemensstraße 10 

 

42551 Velbert
Tel.: +49 2051 278-0 

 

Fax: +49 2051 278-167 

 

E-Mail: [email protected]  
Please contact your retail partner in case of complaints 

or service requirement.

1.2 

Target group of this documentation

These instructions are intended for end users. 

1.3 

Intended use

• 

The multi-point lock is suitable for use in single-sash 

and double-sash doors in permanent buildings.

• 

The multi-point lock may only be installed in doors 

that have been fitted in a technically sound manner.

• 

The door design must permit use of the multi-point 

lock.

1.4 

Locking part and hardware

• 

Repair of the multi-point lock is not permissible. 

 

If the multi-point lock is damaged, it must be repai

-

red or replaced by KFV or by a specialist company.

• 

Use only KFV frame parts.

1.5 

Improper use

• 

The multi-point lock must not be used for escape 

doors.

• 

The multi-point lock must not be used in doors for 

wet rooms or rooms in which the air contains 

 

aggressive or corrosive components.

• 

Foreign objects and/or materials which impede or 

prevent proper use must not be placed within the 

opening range, the locking system or the striker 

plates. 

• 

Do not interfere with and/or make any 

modifications to the multi-point lock.

1.6 

Service notes

• 

Check that all moving components are functioning 

properly once a year.

• 

Please get in touch with your contractual partner if 

you notice malfunction or damage.

1.7 

Dimensions

All measurements are given in mm.

1.8 

Symbols used

The following icons are used in this document:

Information

Do not use mechanical force

Continue reading the instructions 

at the corresponding point

 

Other types of indicators

Below is a list of symbols used in these instructions and 

their meanings:

• 

Items of text following this marker are found in lists.

– 

Items of text following this marker are found 

in subordinate lists.

 

f

Items of text with this marking in front of them are 

instructions that must be followed in the specified 

order.

Cross reference

„“  A separate cross reference is enclosed by 

quotation marks.

()  A cross reference in the flow text is enclosed by 

brackets.

1.9 

Appropriate disposal

• 

The multi-point lock and the optional accessories 

should not be disposed of with household waste. 

Comply with the current local and national 

regulations.

• 

The packaging consists of raw materials that can be 

recycled and can be taken to the local waste paper 

disposal site.

Summary of Contents for A 1100

Page 1: ...Comfort systems Door systems Window systems OPERATING INSTRUCTIONS KFV Multi point locks Key operated BS 2100 BS 2800 A 1100 A 1800...

Page 2: ...H47 MFVRS006EN 01...

Page 3: ...roup of this documentation 4 1 3 Intended use 4 1 4 Locking part and hardware 4 1 5 Improper use 4 1 7 Dimensions 4 1 8 Symbols used 4 1 9 Appropriate disposal 4 2 SAFETY 5 2 1 Causes of damage 5 3 VA...

Page 4: ...used for escape doors The multi point lock must not be used in doors for wet rooms or rooms in which the air contains aggressive or corrosive components Foreign objects and or materials which impede...

Page 5: ...acts that require increased attention 2 1 Causes of damage The lever handle and key must not be operated at the same time Only apply pressure to the lever handle in the direction of activation Max 150...

Page 6: ...FV Operating instructions Multi point locks key operated key operated BS 2100 BS 2800 A 1100 A 1800 The door leaf must not be carried using the lever handle as a grip Double leaf doors must not be for...

Page 7: ...BS 2100 BS 2800 A 1100 A 1800 3 Variants and components Two variants of the multi point lock are available with comfort mushroom cam 1 or with roller bolt 2 An extension piece 3 or 4 with an additiona...

Page 8: ...r activate the key and the lever handle simultaneously 4 1 Locking elements 4 1 1 Function of the latch 1 3 4 2 The latch 1 keeps the door closed in the released condition It enga ges in the AT piece...

Page 9: ...KFV Operating instructions Multi point locks key operated key operated BS 2100 BS 2800 A 1100 A 1800 f f Activate the lever handle or turn the key to the stop in the direction of release The latch wil...

Page 10: ...of main lock bolt and cams 2 f f Shut the door The latch engages in the stop piece The main lock bolt 1 and cams 2 are in the released position 1 1X Single turn locking f f Turn the key once in the r...

Page 11: ...ly The cams retract completely into the frame parts and the door leaf moves laterally to the seal Always turn the key twice to lock the door Only then do the main lock bolt and cams move directly into...

Page 12: ...00 BS 2800 A 1100 A 1800 2X Release f f Turn the key in the unlocking direction with a double turn The main lock bolt extends com pletely into the lock case The cams extend completely out of the frame...

Page 13: ...ck is not permissible In case of damage or functional disorder the multi point lock must be repaired or replaced by KFV or by a specialist company Get in touch with your contractual partner for this L...

Page 14: ...re that the cams do not touch the inlet edge of the frame part while opening or closing the door In the course of time the door leaf could jam or the travel range of the cams could be reduced due to p...

Page 15: ...S 2800 All components of the multi point lock have already been treated with long term lubrication and are consequently maintenance free However if a subsequent lubrication of the locking elements sho...

Page 16: ...www siegenia com H47 MFVRS006EN 01...