56
Scripts and switching functions
•
Setting the user to Do not disturb:
If this function is activated, no user
or device calls are indicated on any of this user’s devices. The user is marked
red in the contact list. Callers receive the engaged tone. The device button
lights up red when the function is active.
•
Parameterized button script
: Individual control script which has been
integrated in the Access server for implementing customer-side special
requests (e.g. special functions or control sequences which are to be
controlled via the Access server), can be assigned to a button with an
Access indoor station and configured via the “Set” button. The scripts
need to be imported into the “Scripts” menu in advance.
The displayed
name Parameterized button script is only an example and can be changed
for the scripts before import.
Remarks
•
If other parameters have to be configured stored for a particular button
assignment (e.g. with one switching point), the button
Setting
becomes
active. After clicking on
Setting
, a dialogue is displayed in which the rel
-
evant required data can be selected or entered.
• The devices or users to which calls can be rerouted depends on the logical
grouping in the user tree and the relevant user rights settings.
• Using
Scripts and switching functions > Switching point
, the
Doormatic function can be assigned to one of the buttons – provided the
Doormatic function is activated for the user to which the device assigned.
Switching outputs/inputs
The number of switching outputs/inputs available for configuration depends
on the equipment of the Access door loudspeaker controller (e.g. additional
extension module).
Switching function
–
Switching
outputs
The functions (
no action, free switching time, door release, door light
)
can be assigned to the relevant switching output.
Switching function
–
Switching
inputs
The functions (
no action, switching point, storey call
, and
signal status
)
can be assigned to this switching output.
Static switching operation (Toggle
0s)
Binary switching operation (ON / OFF)
Timed switching operation (door
release / door light / free switching
time)
Free switching time - timed switching operation (for door release / door light
/ free switching time): ON for (
0.4 s
/
1-59 s
/
1-10 Min
/
15-20-…-55 Min
/
1-12 h
) / OFF / (
0 s
) Toggle
Inverted
The functions
Free switching time
,
Door release
and
Light switching
can be operated inverted (ON becomes OFF / OFF becomes ON).
6
Configuration – Access System
Server administration – device parameters