29
ATLC/NG 670-0
Access door loudspeaker controller
with line rectifier in switch panel
housing as an interface for the con
-
nection and power supply of door
components to the Access network.
Set consisting of ATLC 670-0 and
ANG 600-0.
ATLC 670-0
Access door loudspeaker controller
in switch panel housing as interface
for connecting the door station to a
network.
Switch contact for door release
and freely programmable switching
input.
Optional connection facility for a
maximum of 3 extension modules
ATLCE 670-…
Supply via ANG 600-0
Supply voltage 48 V DC
Output voltage: 10–16 V
Output current:
max. 700/300 mA AC/DC
Contact type: Contact 30 V, 2 A
Protection system: IP 20
Ambient temperature:
0 °C to +40 °C
Horizontal pitch (HP): 6
Dimensions (mm) W x H x D:
107 x 89 x 60
Distribution components – Door controller
ANG 600-0
Access line rectifier in switch panel
housing for power supply e.g. to
the ATLC 670-… with 230 V AC
switching contact.
Admissible switching output:
• Light bulbs max. 1300 W
• Fluorescent lamps max. 800 W
• Twin fluorescent lamps
max. 1200 W
• Parallel compensated fluorescent
lamps max. 400 W
Operating voltage: 100–240 V AC,
+/-10 %, 50/60 Hz
Operating current: 0.5–1 A
Output voltage: 48 V DC
Output current: 800 mA
Fusing: primary T 2 A, secondary
short circuit proof
Contact type: changeover switch
max. 250 V AC, 6 A
Protection system: IP 20
Ambient temperature:
0 °C to +40 °C
Horizontal pitch (HP): 6
Dimensions (mm) W x H x D:
107 x 89 x 60