10 Servicing
LED displays
ATLC 670-0
LED display
LED operating status
Functional characteristics
LED 1
off
no operating voltage
lights up in green
operating voltage applied
Link
lights up in green
connection to switch exists
flashes green
data communication with the device
off
no connection to the switch
Status
lights up in green
Vario bus ready for operation
flashes green
data communication in the Vario bus
Error/OK
lights up briefly in green
after Power On for around 5 seconds
flashes green
during ramp-up, flashing starts up appr. 20 seconds after
Power On
lights up in green
ATLC is logged in at the server
lights up in red
error logging into server
A1
lights up in green
output 1 HIGH (DR)
off
output 1 LOW (DR)
A2
lights up in green
output 2 HIGH
off
output 2 HIGH
A3
lights up in green
output 3 HIGH (LI)
off
output 3 LOW
E
lights up in green
input 1 HIGH (LI)
off
input 1 LOW
ATLC 670-0
SN 0000000000
IP 20
Access Türlautsprecher-Controller
Access Door loudspeaker controller
Access Contrôleur de platine de rue
Link
Status
Error / OK
A1 A2 A3 E
23 24 13 14
15 16 17 18
S1 S2 S3 S4 D1 D2 V1 V2
Output
Input