Functional Description of the Connectors/Interfaces
44
Hardware Description 0360520xx
sinudyn-36
8.2.8
X20 - Motor Connector
X
4-pole PowerCombiCon
Requirements to the motor cable:
The maximum admissible length of the motor cable is 100 m. The capacity must not
exceed 5.2 nF.
Example: If the cable capacity is 0.26 nF per meter, the maximum admissible length
of the motor cable is 20 m.
Pin
Connector
Designation
shield bar at the servo
amplifier
Shield
Ground the motor housing in the machine!
1
U
motor phase U
2
V
motor phase V
3
W
motor phase W
4
PE
protective conductor
Information about the Shield and Ground Connection
Always use shielded motor cables!
With respect to the ground connection one of the following actions
must
be done:
X
connect the motor housing to the ground of the machine or
X
connect the ground terminal of the motor connector to the cen-
tral ground point of the machine.
The cable shield must be connected to the connector shell at the
motor and to the shield bar at the servo amplifier.