9
Connector Pin Assignment
9.1
X66 – Safe Frequency Monitor (SFM)
Connection of the safety function SFM via 2-channel OSSD signal
10-pole Mini-Combicon connector, suitable for mating connector MC 1,5/ 10-ST-3,5
(Phoenix)
Mating connector
X66
Function
Name
Meaning
Pin
I/O
Drive A
SFM_IN_1
OSSD input signal (1st channel)
3
I
SFM_OUT_1
OSSD output signal (1st channel)
4
O
SFM_IN_2
OSSD input signal (2nd channel)
7
I
SFM_OUT_2
OSSD output signal (2nd channel)
8
O
Drive B
SFM_IN_1
OSSD input signal (1st channel)
1
I
SFM_OUT_1
OSSD output signal (1st channel)
2
O
SFM_IN_2
OSSD input signal (2nd channel)
5
(coded)
I
SFM_OUT_2
OSSD output signal (2nd channel)
6
O
Ground
GND
Reference ground
9
I/O
Source
OSSD1
OSSD test signal 1
(1)
10
O
(1)
The OSSD test signal is used for test purposes. This OSSD output is neither certified nor safety-related.
Specification of terminal connections
▶
Conductor cross-section solid/stranded: 0.2 to 1.5 mm²
▶
Connection method: spring-cage connection (handling: see
Related topics
Connection example: "Transmission of the Status Message", page 14
9.2
X67 – Safe Limited Output Frequency (SLOF)
Connection of the safety function SLOF via 2-channel OSSD signal
W
Connector Pin Assignment
Drive System SD2 - Safety Functions SFM / SLOF
57
9
Summary of Contents for SD2
Page 1: ...Drive System SD2 Safety Functions SFM SLOF P TD 0000426 12 2019 08 28 SIEB MEYER W ...
Page 4: ...Chapter Overview W 4 Drive System SD2 Safety Functions SFM SLOF ...
Page 10: ...General Information W 10 Drive System SD2 Safety Functions SFM SLOF 2 ...
Page 16: ...Safe Frequency Monitor SFM W 16 Drive System SD2 Safety Functions SFM SLOF 3 ...
Page 44: ...Fieldbus Communication W 44 Drive System SD2 Safety Functions SFM SLOF 6 ...
Page 56: ...OSSD Signals W 56 Drive System SD2 Safety Functions SFM SLOF 8 ...
Page 66: ...Error Messages W 66 Drive System SD2 Safety Functions SFM SLOF 10 ...