Standardized cross-sections of round conductors:
ISO cross-section [mm²]
AWG/MCM
Value
Equivalent cross-section [mm²]
0,2
24
0,205
–
22
0,324
0,5
20
0,519
0,75
18
0,82
1,0
–
–
1,5
16
1,3
2,5
14
2,1
4,0
12
3,3
6,0
10
5,3
10
8
8,4
16
6
13,3
25
4
21,2
35
2
33,6
50
0
53,5
70
00
67,4
95
000
85,0
–
0000
107,2
120
250 MCM
127
150
300 MCM
152
185
350 MCM
177
240
500 MCM
253
300
600 MCM
304
The line corresponds to a value when the connection possibilities are taken
into account.
12.2.1
Motor Cable
DANGER
Dangerous shock currents
Earthing and shielding measures are required to protect devices and persons. To
ensure the safety of the operator earthing must be carried out with low impedance.
With respect to the ground connection one of the following actions must be done:
▶
connect the motor housing to the ground of the machine or
▶
connect the ground terminal of the motor connector to the central ground point
of the machine.
Consider the following with regard to shielding: Always use shielded motor cables!
W
General Information Regarding the Wiring
Drive System SD3 - Hardware Description
73
12
Summary of Contents for Drive System SD3 Series
Page 1: ...Drive System SD3 Hardware Description P TD 0000486 3 2017 03 30 SIEB MEYER W...
Page 4: ...Chapter Overview W 4 Drive System SD3 Hardware Description...
Page 8: ...Content W 8 Drive System SD3 Hardware Description...
Page 20: ...Safety Instructions W 20 Drive System SD3 Hardware Description 3...
Page 22: ...Unit Assembly Complying EMC W 22 Drive System SD3 Hardware Description 4...
Page 28: ...Description of the Device W 28 Drive System SD3 Hardware Description 5...
Page 60: ...9 3 X19 Encoder 1 Connection Examples W 60 Drive System SD3 Hardware Description 9...
Page 66: ...Connection Examples W 66 Drive System SD3 Hardware Description 9...
Page 68: ...Status Display and Error Messages W 68 Drive System SD3 Hardware Description 10...
Page 70: ...Battery Change W 70 Drive System SD3 Hardware Description 11...
Page 76: ...General Information Regarding the Wiring W 76 Drive System SD3 Hardware Description 12...
Page 82: ...Safety Circuit Restart Lock STO W 82 Drive System SD3 Hardware Description 13...