7.8
X13/X14 – Fieldbus IN/OUT
Fieldbus extension for the connection of a PLC (no retrofit possible)
2 × 8-pole female RJ45 connector, shielded
X13 IN
Pin/LED
I/O
Name/Color
Meaning
8
7
I/O
VC−
PoE (NC)
6
I
RX−
Receive data −
5
4
I/O
VC+
PoE (NC)
3
I
RX+
Receive data +
2
O
TX−
Transmit data −
8
1
1
O
TX+
Transmit data +
X14 OUT
Pin/LED
I/O
Name/Color
Meaning
8
7
I/O
VC−
PoE (NC)
6
I
RX−
Receive data −
5
4
I/O
VC+
PoE (NC)
3
I
RX+
Receive data +
2
O
TX−
Transmit data −
8
1
1
O
TX+
Transmit data +
The fieldbus interface can be delivered with various optional Ethernet real-time proto-
cols.
LED states
The status of the real-time Ethernet connection is indicated via the LEDs at the female
RJ45 connectors and depend on the bus protocol.
For a description of the fieldbus LEDs at the device refer to
.
EtherCAT:
Female RJ45
connectors
LED
Status
Meaning
Off
No connection
Green
Link:
The device has established a con-
nection with Ethernet, but does not send/re-
ceive Ethernet frames.
LED 0
Flickers green
(load-dependent)
Activity:
The device has established a con-
nection with Ethernet and sends/receives
Ethernet frames.
X13 / X14
0
1
8
1
LED 1
Off
This LED is not used.
77
Drive System SD4S - Hardware Description
Connectors