Drive Amplifier SD4S
5.5
Rear Panel Mounting
Note
SD4S devices must be installed in a switch cabinet.
The device is designed for vertical rear panel mounting. Other setup positions are pos-
sible but you must consult SIEB & MEYER before.
Suitable fastening screws: M6 according to ISO 4762
▶
strength class: 8.8
▶
washers: 6.6 x 22 x 2 mm according to ISO 7094
Note: Using the washers is required to achieve class 3M2 (mechanical stability).
▶
minimum engagement depth in the mounting plate: 5 mm for steel, 8 mm for alu-
minum
Note
The rear panel of the device must fit flat against the mounting plate. If you use locking
threads, make sure that these do not protrude beyond the mounting plate.
5.6
General Technical Data
The following data apply to all devices of the series SD4S.
5.6.1
Storage and Transport
Avoid improper mechanical load of the device. The following points must especially be
taken into consideration:
▶
Never touch electronic components.
▶
Avoid stacking of unpacked devices during transport and storage.
▶
Sudden changes of the temperature must not exceed 0.5 °C/min.
The following climatic conditions apply to transport and storage. If required, appro-
priate measures must be taken to ensure these climatic conditions (installation of
heating/air conditioning systems etc.):
Environmental conditions
Storage acc. to IEC
60721-3-1 in product pack-
age (up to 6 months)
(1)
Transport acc. to IEC
60721-3-2 in shipping
package (over 6 months)
Climatic conditions
Class 1K4
Class 2K3
Min.
−25 °C
−25 °C
Ambient temperature
(2)
Max.
55 °C
70 °C
Vibrations
Class 1M2
Class 2M1
Chemically active substances
Class 1C1
Class 2C1
Relative/absolute humidity
Class 1K3 (5 %
RH to 85 % RH)
Class 2K3 (5 %
RH to 85 % RH)
Rain
Not permissible
Not permissible
Water (not rain)
Not permissible
Not permissible
Condensation, water spray and ice
Not permissible
Salt spray
Not permissible
Tab. 1: Environmental Conditions for Storage and Transport
(1)
The product package used by SIEB & MEYER does not comply with the standard of shipping package.
In addition, it does not provide protection against water spray, ice and salt spray.
(2)
The limit values apply with the coolant removed.
22
Drive System SD4S - Hardware Description