General Information
TÜV SÜD Product Service is an NRTL approved by OSHA and undertakes product cer-
tifications for industrial controls, electric drives and other products. The following links
lists the approved NRTL laboratories:
https://www.osha.gov/dts/otpca/nrtl/nrtllist.html
The tested devices are labeled with the following symbol:
The device series SD2B plus is tested accoring to the harmonized standard IEC / UL
61800-5-1: „Standard for Adjustable Speed Electrical Power Drive Systems - Part 5-1:
Safety Requirements - Electrical Thermal and Energy‟
▸
Date: 2020/07/23
▸
Device variants: 0362171DA1xxxx, 0362171DB1xxxx
▸
Certificate number: U8V 096098 0007 REV. 00
▸
Certificate data base:
https://www.tuev-sued.de/product-testing/certificates
(Enter „
SIEB & MEYER
AG‟ in the search field.)
http://www.tuev-sued.de/industry-and-consumer-products/-services/nationally-
recognized-testing-laboratory-nrtl
http://www.tuev-sued.de/industry-and-
consumer-products/-branches/industrial-electronics/
2.2
NRTL Requirements
Points of Exceptions of the Test Procedure and Conditions of Acceptability
Conditions of Acceptability:
▸
Power Drive System ((building in; open frame)
▸
When installing, requirements of mentioned Test Standards and Installation Guide
have to be fulfilled.
▸
The equipments are intended for use in end-use application within final enclosure
to maintain a Pollution Degree 2 or equivalent environment.
▸
The final enclosure has to fulfill the requirements for the protection in case of direct
contact.
▸
The equipment shall not be installed over and below a flammable surface.
▸
Supply System: System Voltage 300 V, Overvoltage Category III or Overvoltage
Category II
▸
Maximum Surrounding Air Temperature: +40 °C.
▸
The Terminal blocks are suitable for factory wiring only.
▸
The end-use application must be equipped with a Branch Circuit Protection that
meets the requirements of the NRTL certificate.
▸
All Branch Circuit Protection shall have characteristic B.
▸
The diameter of the protective earthing conductor shall be 10 mm² (AWG 8) or high-
er.
▸
Construction Test only
▸
SFC (Single Fault Condition) are not included.
8