Connector Pin Assignment
Hall Sensor 5.3 V, page 42
PULSE IN 5.3 V, page 42
6.11
X26/ X27 – SERVOLINK 4
SERVOLINK 4: optical input (X26) and optical output (X27)
The fiber optic connectors for SERVOLINK 4 are located at the top of the device.
Connector
SIEB & MEYER article number
12540102
Inputs (black)
12540103
12540202
Outputs (gray or white)
12540203
Cable connector
(TOSLINK F05)
32022900
NOTICE
Risk of cable damage
If you pull the optical fiber cable with its connector too fast out of the connector, the cable
may be damaged.
→ When unplugging the cable, hold the fiber optic connector and pull the cable care-
fully out of the connector.
Related topics
6.11.1
Preparation of Optical Fiber Cables with
Connector
Every optical fiber connector requires an optical fiber cable with a male connector. The
following information apply for connectors used in applications with 1 mm standard plas-
tic optical fibers (POF).
30
Drive Amplifier SD2B plus - 0362171DA1xxxx, 0362171DB1xxxx