Note
Solid wires or conductors with ferrules can be put directly into the chamber without the
help of a screwdriver.
6.2.2
Push-in technology
Terminals using the push-in connection technology
(PIT) work on the pressure spring principle:
The contact spring presses the cable against the con-
ducting copper bar. The special spring profile allows
direct and tool-free wiring of solid and stranded cables
previously assembled with ferrule or compressed con-
ductor ends.
▸
When the cable is inserted into the clamping unit
the spring opens automatically.
▸
To open the clamp and loosen the cable use a
screw driver.
6.3
ID Switch (Address Selection Switch)
➮
Set the address for the module by means of the address selection switch.
16 adresses are available: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, F. (When the de-
vice is connected via SERVOLINK 4 only 12 addresses are available (0 to B).)
Note
The addresses of several devices in a system must be different from each other to
ensure that they can be identified by the software.
6.4
X10 – COM1/Operating Terminal
9-pole male submin D connector
X10
Pin
I/O
Name
Meaning
1
O
VCC
5.3 V (power supply for optional operat-
ing terminal, short-circuit proof)
2
I
RX
RS232 Interface 1
3
O
TX
RS232 Interface 1
4
I/O
CAN_L
CAN_L
5
I/O
GND
Ground
6
I
RX2
RS232 Interface 2
7
O
TX2
RS232 Interface 2
8
I/O
CAN_H
CAN_H
9
I/O
GND
Ground
Locking bolts flange: max. tightening torque = 0.7 Nm