In the menu item SELECT PARAMSET, the parameter set that is currently stored in the
RAM is displayed.
Via the “Cursor up” and “Cursor down” keys, you can select a new parameter set.
Press ENTER to confirm your selection and to apply the new parameter set. Then,
there is a change-over in the drive, which can take some seconds.
Via the ESC key, you can cancel your selection that will then be rejected. Once you
finished your selection, the display will switch to the AUTOMATIC MODE.
14.3.5
READ PARAMETER
Note
You must enter the correct password to open this menu item.
When the parameters are read, all parameter sets saved in the Flash EPROM of the dri-
ve are loaded into the Flash EPROM of the operating terminal. The terminal displays the
currently loaded parameter page, so you can follow the download progress.
After successful reading, the following message appears:
If there is an error during reading, the process will be canceled and the following error
message will be displayed:
If there are no parameters stored in the drive, the following error message will appear:
33
Drive System SD2x - Operating Terminal 0362150 and 0362153
Functions of the Terminal