7
MAINTENANCE AND REPAIR
102
8023994-17I6/2020-03-19|SICK
O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS4100/5100
Subject to change without notice
7.1.7
Cleaning the cabinet
The cabinet features an integrated fan to ensure that cabinet components are adequately
cooled.
▸
Air inlets and outlets on the cabinet should be cleaned regularly with a brush.
WARNING!
RISK OF DAMAGE TO ELECTRONIC DEVICES
▸
Never use compressed air for cleaning!
▸
Only knock the dirt off the ventilation grilles or clean them with a brush.
▸
Never wet-clean the grilles.
Fig. 89: Replacing the filters at the air inlets and outlets of the cabinet
▸
Regularly check and, if necessary, replace the filter mats behind the covers for the air
inlets and outlets.
▸
Remove the covers from the air inlets and outlets. To do this, insert your finger into the
semi-circular recess in the cover.
▸
Carefully remove the cover from the front.
▸
Remove old filter mats and replace them with new ones.
Reattach the covers the right way up and press them down until they click into place.
Cleaning
Replacing
filter mats