![SICK Visionary-B CV Operating Instructions Manual Download Page 95](http://html.mh-extra.com/html/sick/visionary-b-cv/visionary-b-cv_operating-instructions-manual_1264355095.webp)
3 D D R I V E R A S S I S TA N C E S Y S T E M | V I S I O N A R Y - B
8022960/2018-07-16| SICK AG
Subject to change without notice
9 5
ANNEX
11
Annex
11.1
Technical data
11.1.1
Features
1)
Working distance
0.5 m ... 7 m
Definable detection zone
(∆x x ∆y)
6 m x 7 m
Maximum detection angle
120° x 75°
Maximum installation angle
(in relation to the horizontal)
must be delimited by the ground
1)
Information refer to the maximum definable detection zone.
11.1.2
Performance
Object class definition
Object class
Objects
Description
1
≥ 40 x 80 cm on the
ground
Can be used for detec-
ting bulk objects like
vehicles, goods and
walls.
2
ca. 40 x 160 cm on
the ground
Can be used in narrow
paths. Bigger objects,
like walls or containers,
will be ignored.
Response time
< 200 ms typical
On delay
< 50 s
11.1.3
Interfaces
Configuration
Software interface, operation via keyboard/mouse/display
11.1.4
Mechanical
Mounting
1 m – 2.4 m
Mounting position
According to the detection zone (must be delimited by the
ground)
Weight of sensor head
1.3 kg
Weight of evaluation unit
3.8 kg
Dimensions
Enclosure rating
IP69K (sensor head), IP 67 (evaluation unit)
11.1.5
Electrical
Supply voltage
12 V DC -10 %
24 V DC +40 %