3 D D R I V E R A S S I S TA N C E S Y S T E M | V I S I O N A R Y - B
8022960/2018-07-16| SICK AG
Subject to change without notice
6 7
PRODUCT DESCRIPTION
3.5.2
Detection zone and alarm zone
h
Max. detection distance
∆y
Installation angle
The detection zone of the sensor head depends on:
•
The distance to a flat boundary surface, such as the ground, a ceiling, a wall, etc.
•
The mounting angle in relation to the ground
•
The ambient conditions
The maximum detection range is preset to 7 m. This value may differ or be physically
delimited due to environmental influences or mounting parameters.
Δy
x,y(0,0)
z
Δx
The maximum definable alarm zone is depending on the specific object class. As "Full-
Performance Zone"
is a maximum area of 4 m x 6 m configurable. In
the "Extended Zone"
there is an area of 6 m x 7 m adjustable.