7.3.3
Digital output 2 teach-in (UC40-xxxxxH only)
7.3.3.1
Factory settings of the digital output
•
N/O contact
•
Switching point at maximum operating range
7.3.3.2
Teaching in switching point (Single Point Mode)
Overview
When the object is located below the taught-in switching point, the digital output is
active.
Approach
Teaching in the switching point (distance to object as switching point)
1
1.
Position the object at
1
.
2.
Press
T1
pushbutton for 3 seconds until
LED 3
and
LED 4
flash simultaneously.
✓
LED 3
and
LED 4
flash alternately.
3.
Press
T1
for 1 second.
✓
The switching point is taught in. The device automatically switches to normal
operation mode.
Teaching in switching point (distance to 8% as switching point)
1.
Position the object at
1
.
2.
Press
T1
pushbutton for 3 seconds until
LED 3
and
LED 4
flash simultaneously.
✓
LED 3
and
LED 4
flash alternately.
3.
Press
T1
for 3 seconds until
LED 3
and
LED 4
flash alternately again.
✓
The switching point is taught in. The device automatically switches to normal
operation mode.
7.3.3.3
Teaching in switching window (Window Mode)
Overview
When the object is located within the taught-in switching window, the digital output is
active.
Approach
2
1
1.
Position the object at
1
.
2.
Press
T1
pushbutton for 3 seconds until
LED 3
and
LED 4
flash simultaneously.
✓
LED 3
and
LED 4
flash alternately.
3.
Position the object at
2
.
✓
LED 3
and
LED 4
flash alternately.
7
OPERATION
24
O P E R A T I N G I N S T R U C T I O N S | UC40
8027772//2022-08-11 | SICK
Subject to change without notice