6
COMMISSIONING
56
8027439/V1-0/2022-02|SICK
A D D E N D U M T O O P E R A T I N G I N S T R U C T I O N S | Track and trace cabinet TTC100-2
Subject to change without notice
6.2
Connecting the configuration PC
6.2.1
Establishing a connection with the configuration PC
The customer application is configured with the SOPAS configuration software. The
configuration software is installed on a PC, which is connected to the SIM2000-2 Prime
controller via an Ethernet cable.
Fig. 33: Establishing a connection between the configuration PC and the controller
▸
Connect the configuration PC to the controller via an Ethernet cable.
▸
On the SIM2000-2 Prime controller, one of the Ethernet interfaces
X11
to
X14
.
NOTE!
It is also possible to establish the connection using an Ethernet switch, to which
both the controller and the configuration PC are connected.
Port SIM2000-2 Prime
IP address
X11 -ETH 1
192.168.0.1
X12 -ETH 2
192.168.1.1
X13 -ETH 3
192.168.2.1
X14 -ETH 4
192.168.3.1
The IP address is altered during configuration.
▸
Make sure that the configuration PC is in the same number range as the controller.
▸
If not, change the IP address of the configuration PC.
Default IP addresses
of the SIM2000-2
Prime