background image

O P E R A T I N G   I N S T R U C T I O N S

TMS/TMM22

Inclination sensor

Summary of Contents for TMM22

Page 1: ...O P E R A T I N G I N S T R U C T I O N S TMS TMM22 Inclination sensor...

Page 2: ...provisions of copyright law Any modification abridgment or translation of this document is prohibited without the express written permission of SICK AG The trademarks mentioned in this document are th...

Page 3: ...that indicate the extent of the danger These warnings must be observed at all times and care must be taken to avoid accidents personal injury and material damage DANGER indicates a situation of immine...

Page 4: ...in accordance with the intended use All information in these operating instructions must be strictly observed 3 3 Requirements for the qualification of personnel The personnel who work on and with th...

Page 5: ...25 and excellent repeatability The measured values are output via a linearized analog signal In order to meet the highest requirements in terms of resistance for outdoor applications such as PV system...

Page 6: ...t temperature max 75 C enclosure type 1 Electrical parameters Supply voltage 12 V DC 30 V DC Current consumption Analog 010 V 50 mA 24 V Analog 4 20 mA 50 mA Iloop 24 V Mechanical parameters Connectio...

Page 7: ...xes TMM X X Y Y Figure 1 TMM22 measuring axis TMS Z Figure 2 TMS22 measuring axis TECHNICAL DATA 5 8026576 1EF6 2021 12 13 SICK O P E R A T I N G I N S T R U C T I O N S TMS TMM22 7 Subject to change...

Page 8: ...2 mA 5 V Figure 3 TMM zero point TMS Sensor mounted vertically Cable points to the left The output of the z axis outputs 4 mA 0 V in this position The second output is not used L Figure 4 TMS zero poi...

Page 9: ...mage that is visible externally proceed as follows Do not accept the delivery or only do so conditionally Note the extent of damage on the transport documents or on the transport compa ny s delivery n...

Page 10: ...1 38 8 1 53 3 3 0 13 3x 3 2 0 13 22 5 0 89 0 1 30 1 18 17 4 0 69 4 8 0 19 8 1 0 32 10 4 0 41 Figure 5 Dimensional drawing 7 MOUNTING 10 O P E R A T I N G I N S T R U C T I O N S TMS TMM22 8026576 1EF6...

Page 11: ...screws A tightening torque of 1 4 Nm must not be exceeded Make sure that the mounting surface is as flat as possible to avoid mechanical stresses and to ensure good measurement results MOUNTING 7 802...

Page 12: ...VS 2 White z axis y axis 3 Blue GND GND 4 Black n c x axis 5 Gray TEACH 1 TEACH 1 1 To activate the zero point setting connect TEACH pin 5 to GND pin 3 for at least 1 second 8 2 Circuit diagrams TMS...

Page 13: ...lts in the following exemplary conductor resistances 1 m length of cable R 0 05 ohm conductor resistance 10 m length of cable R 0 50 ohm conductor resistance 30 m length of cable R 1 51 ohm conductor...

Page 14: ...26 27 28 29 30 0 250 500 750 1000 1250 Input voltage U V Load resistance R Figure 9 Permissible load resistances 8 CONNECTION 14 O P E R A T I N G I N S T R U C T I O N S TMS TMM22 8026576 1EF6 2021 1...

Page 15: ...side of the sensor The counting directions can be found in see figure 10 page 15 The axis of rotation of the TMS22 single axis sensor runs vertically through the sensor surface and covers a complete...

Page 16: ...operation TEACH should be permanently set to US Performing the zeroing process results in both outputs of the TMM22 giving out 12 mA or 5 V in the current position while the output of the TMS22 is set...

Page 17: ...sful It then again lights up permanently Red LED The red LED indicates that there is a fault As long as this LED is flashing the outputs are automatically deactivated This is the case for example if t...

Page 18: ...examples for four variants TMM22E Pxx090 Figure 14 TMM22E Pxx090 output diagram TMM22E Pxx045 Figure 15 TMM22E Pxx045 output diagram TMS22E Pxx360 Figure 16 TMS22E Pxx360 output diagram 9 DESCRIPTION...

Page 19: ...generated via a 14 bit DAC transducer This results in a resolution depending on the measuring range as shown in see figure 18 page 19 Figure 18 Resolution vs set measuring range Examples TMM22E Pxx090...

Page 20: ...ts and that the standards and or technical specifications stated in the EU declaration of conformity have been used as a basis for this 10 3 Compliance with UK statutory instruments UK declaration of...

Page 21: ...ANNEX 10 8026576 1EF6 2021 12 13 SICK O P E R A T I N G I N S T R U C T I O N S TMS TMM22 21 Subject to change without notice...

Page 22: ...080 7425 E Mail enquiry my sick com Mexico Phone 52 472 748 9451 E Mail mexico sick com Netherlands Phone 31 0 30 229 25 44 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree E...