6.4.1
TiMxxx-21xxxxx
“Power/I/O” connection
3
1
7
2
6
5
4
8
9
10
12
11
Table 7: Male connector, M12, 12-pin, A-coded
Pin
Signal
Function
Wire colors connecting
cable part no. 6054974
(5 m), 6054973 (10 m),
6054972 (20 m)
1
1
GND
Ground
Blue
2
DC 9 V ... 28 V
Supply voltage
Brown
3
IN 1
Switching input 1 (field set selection) Red
4
IN 2
Switching input 2 (field set selection) Green
5
OUT 1
Switching output 1 (field breach)
Pink
6
OUT 2
Switching output 2 (field breach)
Yellow
7
OUT 3
Switching output 3 (field breach)
Black
8
OUT 4
Switching output 4 (index/error)
Gray
9
INGND
Common ground for all inputs
White
10
IN 3
Switching input 3 (field set selection) Violet
11
IN 4
Switching input 4 (field set selection) Gray + pink
12
N.c.
–
Red + blue
–
–
Screen
1
Example values when using the specified connecting cable(s). Signal assignment and wire colors can
vary when using other connecting cables.
"Ethernet" connection (only TiMxxx-21xxxxx)
1
4
3
2
Table 8: Female connector, 4-pin, D-coded
Contact
Labeling
Description
1
TX+
2
RX+
R
3
TX-
Sender-
4
RX-
Receiver-
6.4.2
USB interface
The Ethernet interface is recommended as a communication interface.
If using the USB interface, please note:
•
Use a high-speed UBS cable, maximum length of cable 3 m.
•
The connection may be interrupted due to ESD/EMC influences. If necessary: Dis‐
connect USB cable from the device, then reconnect it. Restart communication via
SOPAS ET software (“Online” button).
6
ELECTRICAL INSTALLATION
32
O P E R A T I N G I N S T R U C T I O N S | TiM781
8024231//2019-03-29 | SICK
Subject to change without notice