![SICK T4000 Direct Unicode Operating Instructions Manual Download Page 39](http://html1.mh-extra.com/html/sick/t4000-direct-unicode/t4000-direct-unicode_operating-instructions-manual_1264706039.webp)
11.2.2
Technical data
Table 8: Technical data of sensors T4000-DNA....
Parameter
Minimum
Typical
Maximum
Housing material
Fortron, fiberglass-reinforced thermoplastic, encapsu‐
lated
Dimensions
42 × 25 × 12 mm³
Weight (incl. 10 m cable)
0.3 kg
Ambient temperature
–25 °C
–
+70 °C
Enclosure rating
IP67/IP69k
Response range
Assured switch-off distance S
ar
Switch-on distance
Assured switchon distance S
ao
Switching hysteresis
With side approach direction
–
–
10 mm
0.5 mm
–
–
15 mm
–
2 mm
3 mm
32 mm
–
–
–
–
T4000DNA..P sensor connection
Permanently encapsulated connecting cable with fer‐
rules
Cable length for sensor T4000-
DNA..P
–
–
15 m
T4000-DNAC sensor connection
Plug connector M8, 3-pin, with latching and screw con‐
nection
Cable length T4000-DNAC
–
–
25 m
11.3
T4000-1KBA actuator
Table 9: Technical data of actuator T4000-1KBA
Parameter
Minimum
Typical
Maximum
Housing material
Fortron, fiberglass-reinforced thermoplastic, encapsu‐
lated
Dimensions
42 × 25 × 12 mm³
Weight
0.02 kg
Ambient temperature
–25 °C
–
+70 °C
Enclosure rating
IP67/IP69k
Installation position
Sensing face opposite sensor
Dwell time
1)
0.5 s
–
–
1)
The dwell time is the time in which the actuator must be located inside or outside the response range.
TECHNICAL DATA
11
8022726/2019-05-07 | SICK
O P E R A T I N G I N S T R U C T I O N S | T4000 Multi
39
Subject to change without notice