Figure 24: Dimensional drawing of “Flat” STR1
actuator
All dimensions in mm.
9
7
23
Ø 3,4
Ø 6,5
4
Figure 25: Dimensional drawing of “Mini” STR1
actuator
All dimensions in mm.
11.3
Response time and release time in a safe series connection
The reaction times are subject to the following parameters:
•
Response time or enable time
•
Number of devices in series connection
Response time (removal of actuator from response range)
Response time for series connection: 40 ms × number of safety switches in series con‐
nection
Enable time (actuator approaching response range)
Release time for series connection: 100 ms × number of safety switches in series con‐
nection
Risk time (error detection time for external faults)
Risk time for series connection: 100 ms +40 ms * (number of safety switches in series
connection -1)