![SICK STR1 Operating Instructions Manual Download Page 25](http://html1.mh-extra.com/html/sick/str1/str1_operating-instructions-manual_1264703025.webp)
6.4
Device connection (M12, 8-pin)
Variants except for STR1-SAXM0AC8S01 and STR1-SAXM0AC8S02
8
2
3
4
5
7
1
6
Figure 15: Device connection (male connector, M12, 8-pin, A-coded)
Table 8: Device connection pin assignment (male connector, M12, 8-pin, A-coded)
Pin
Wire color
1)
Designation
Description
1
White
Aux
Application diagnostic output
(not safe)
2
Brown
+24 V DC
Voltage supply 24 V DC
3
Green
n. c.
Not connected
4
Yellow
In 2
Enable input OSSD 2
2)
5
Gray
OSSD 1
OSSD 1 output
6
Pink
OSSD 2
OSSD 2 output
7
Blue
0 V
Voltage supply 0 V DC
8
Red
In 1
Enable input OSSD 1
2)
1)
Applies to the connecting cables recommended as accessories.
2)
When using an individual safety switch or in a series connection with T-connector, apply 24 V DC on the
first safety switch (
see "Safe series connection with T-connector (without diagnostics)", page 17
).
Only for variants STR1-SAXM0AC8S01 and STR1-SAXM0AC8S02
8
2
3
4
5
7
1
6
Figure 16: Device connection (male connector, M12, 8-pin, A-coded)
Table 9: Device connection pin assignment (male connector, M12, 8-pin, A-coded)
Pin
Wire color
1)
Designation
Description
1
White
+24 V DC
Voltage supply 24 V DC
2
Brown
In 1
Enable input OSSD 1
2)
3
Green
0 V
Voltage supply 0 V DC
4
Yellow
OSSD 1
OSSD 1 output
5
Gray
Aux
Application diagnostic output
(not safe)
6
Pink
In 2
Enable input OSSD 2
2)
7
Blue
OSSD 2
OSSD 2 output
8
Red
n. c.
Not connected
1)
Applies to the connecting cables recommended as accessories.
2)
When using an individual safety switch or in a series connection with T-connector, apply 24 V DC on the
first safety switch (
see "Safe series connection with T-connector (without diagnostics)", page 17
).
ELECTRICAL INSTALLATION
6
8018754/12IU/2020-01-30 | SICK
O P E R A T I N G I N S T R U C T I O N S | STR1
25
Subject to change without notice