background image

 EN

SiLink2 Master
IOLA2US-01101

IO-Link USB Master

OperAtIng InStrUctIOnS

Summary of Contents for SiLink2 Master IOLA2US-01101

Page 1: ...EN SiLink2 Master IOLA2US 01101 IO Link USB Master Operating Instructions ...

Page 2: ...17387 Copyright protection This work is protected by copyright The resulting rights are retained by SICK AG Duplication of this work is only permitted within the bounds of the statutory regulations of the Urhebergesetz Copyright Act The work may not be altered or abridged without the express written permission of SICK AG ...

Page 3: ...Incorrect Use 7 2 3 Requirements for Qualified Personnel 8 3 Identification 9 3 1 Type Label 9 4 Structure and Function 9 4 1 Structure 9 4 2 Function 10 4 3 Status Indicators 10 5 Electrical Connection 11 5 1 Safety 11 5 2 Electrical Connection of SiLink2 Master 11 5 3 Connection Diagram 12 5 3 1 USB Connection Diagram 12 5 3 2 IO Link Connection Diagram 12 6 Installing Software 13 6 1 Required S...

Page 4: ...ter SiLink2 Master Table of Contents 4 SICK AG Presence Detection Subject to change without notice 8017387 10 Technical Data 17 10 1 Dimensions 17 10 2 Supply and Interface 18 10 3 Ambient Conditions 18 10 4 Design Configuration 18 Index 19 ...

Page 5: ...used by qualified personnel and electrical specialists 1 2 Explanation of Symbols Physical Damage Warnings in these operating instructions are labeled with symbols The notes must be complied with and careful actions must be taken in order to avoid physical damage WARNING indicates a possible hazardous situation which may lead to physical damage if it is not avoided Tips and Recommendations NOTE hi...

Page 6: ...ice department will be happy to help See the back page for your representative NOTE In order to allow us to deal with the matter quickly please note down the type designation and order number before calling You can find the type designation and order number on the type label See Page 9 Chapter 3 1 1 5 EC Declaration of Conformity You can download the EC declaration of conformity online at www mysi...

Page 7: ...sed configuration program SICK AG accepts no liability for direct or indirect losses or damage which result from the use of the product This applies in particular for a different use of the product which does not comply with the intended purpose and is not described or mentioned in this document 2 2 Incorrect Use The SiLink2 Master IOLA2US must not be used in explosion areas All uses not described...

Page 8: ...work Qualified personnel are able to carry out the work assigned to them and independently recognize potential risks due to their specialist training knowledge and experience as well as knowledge of the relevant regulations Electrical specialists are able to carry out work on electrical systems and independently recognize potential risks due to their specialist training knowledge and experience as...

Page 9: ...e 3 CE mark 4 Device type 5 Order number 6 Labeling Mini USB B interface side 7 LED labeling side 8 Manufacturer address 9 Labeling of the connection of an external wall plug side 4 Structure and Function 4 1 Structure 1 2 3 4 5 6 7 Fig 2 Structure of SiLink2 Master 1 Supply voltage DC 24 V connection of supplied power supply 2 Function display LED yellow PWR 3 Mini USB B connection of PC via supp...

Page 10: ...PAS ET or an FDT based configuration program 4 3 Status Indicators Function Displays LEDs Function Display Description PWR LED yellow supply via the USB port LED off no operation CH1 C Q Display IO Link and SIO mode LED green Slow flashing no IO Link connection present Quick flashing IO Link connection is in the Preoperate mode Illuminated a data exchange operate is taking place via the IO Link co...

Page 11: ...ion of SiLink2 Master 2 USB IO Link PC SiLink2 Master IO Link Device 1 Fig 3 Electrical Connection of SiLink2 Master 1 USB cable 2 Sensor cable 1 Ensure power supply is not connected 2 Connect the PC to the USB Mini B female connector of the SiLink2 Master using the supplied USB cable 3 Connect IO Link device to the M12 male connector of the SiLink Master using a sensor cable A 3 pole or 4 pole ca...

Page 12: ...ill need to use the supplied wall plug Fig 4 Wall plug pin assignment 5 3 Connection Diagram 5 3 1 USB Connection Diagram 1 2 4 3 5 Fig 5 Mini USB B connection diagram Contact Signal Description 1 5 V VBUS 5 V DC 500 mA 2 D Data 3 D Data 4 ID nc not assigned 5 GND Ground 0 V Table 2 Description Mini USB B 5 3 2 IO Link Connection Diagram 1 2 4 3 5 Fig 6 IO Link connection diagram M12 male connecto...

Page 13: ...ther need the SOPAS ET configuration program from SICK or a configuration program based on FDT DTM technology NOTE For additional information and for configuration programs go to www mysick com de silink 6 2 Installation with SOPAS ET Configuration Program You can use the SOPAS ET configuration program from version 2 83 upwards 1 Start installation of the SOPAS ET configuration program using the s...

Page 14: ...e Page 11 Chapter 5 5 Connect IO Link device according to the Connection Wizard for IO Link Fig 8 IO Link device in SOPAS ET 6 3 Installation with FDT Container You can use the gateway DTM from version 2 00 upwards 1 Start installation of the gateway using the setup exe file 2 Install DTM of the IO Link device or IODD interpreter In order to do this start installation using the setup exe file 3 Up...

Page 15: ...talog as IO Link USB of the manufacturer IO Link 4 Set up network in the configuration program 5 Connect SiLink2 Master to the PC and IO Link device See Page 11 Chapter 5 6 Set up connection in the configuration program 7 Open user interface of the IO Link device by double clicking on the IO Link device or via the context menu in the configuration program Fig 10 Open user interface of the IO Link ...

Page 16: ...he screw and plug connections and cleaning the device at regular intervals 8 Troubleshooting Indication Possible Cause Troubleshooting Red LED Error illuminated Data transmission error Transmit data again Short circuit Change SiLink2 Master Table 4 Troubleshooting 9 Disposal Observe the following points for disposal Do not dispose of the device in domestic refuse Dispose of the device according to...

Page 17: ...online at www mysick com de silink 10 1 Dimensions 1 2 3 4 5 6 7 41 1 61 54 2 13 16 0 63 M 12 Fig 11 Dimensions of IO Link USB Master SiLink2 Dimensions with no brackets in mm Dimensions with brackets in inches 1 Supply voltage DC 24 V connection of supplied power supply 2 Function display LED yellow PWR 3 Mini USB B connection of PC via supplied USB cable 4 Function display LED green C1 C Q 5 Fun...

Page 18: ...safety Yes IO Link communication IO Link specification 1 1 IO Link port Class A Table 5 Supply 10 3 Ambient Conditions Mark of conformity CE Protection class III Ambient temperature range Operation 0 C 45 C Storage 40 C 80 C Enclosure rating IP 20 Table 6 Ambient conditions 10 4 Design Configuration Dimensions See Page 17 Chapter 10 1 Connections 1 female connector connection of external wall plug...

Page 19: ...mity 6 Electrical connection SiLink2 Master 11 Electrical specialist Requirement 8 Explanation of symbols 5 F FDT DTM 13 Function 10 Function displays 10 I Incorrect use 7 IO Link Connection diagram 12 Interface 18 IO Link mode 10 L LEDs 10 M Maintenance 16 O Operating instructions 5 Q Qualified personnel 8 Requirements 8 S Safety 7 Electrical connection 11 Scope of delivery 5 SIO mode 10 Software...

Page 20: ...an Phone 81 0 3 3358 1341 e mail support sick jp Hungary Phone 36 1 371 2680 e mail office sick hu Netherlands Phone 31 0 30 229 25 44 e mail info sick nl Norway Phone 47 67 81 50 00 e mail sick sick no Austria Phone 43 0 22 36 62 28 8 0 e mail office sick at Poland Phone 48 22 837 40 50 e mail info sick pl Romania Phone 40 356 171 120 e mail office sick ro Russia Phone 7 495 775 05 30 e mail info...

Reviews: