1
2
3
Figure 22: Inserting the safety light curtain in the FlexFix brackets
NOTE
The protective device can only be screwed in when both brackets are in alignment.
Recommendation:
1.
Only hand-tighten the screws on the brackets at first.
2.
Align the two brackets. To do this, place a straightedge or spirit level, for example,
on the screw mounting surfaces of the brackets that are not being used.
3.
Tighten the screws.
Further topics
•
"Sender and receiver alignment", page 47
•
5.2.3
Mounting the Compact FlexFix bracket
Overview
With a Compact FlexFix bracket, you can mount the sender and receiver closer to the
machine or profile frame.
2 Compact FlexFix brackets are used to mount the sender and receiver.
In the Compact FlexFix bracket, the sender and receiver can be rotated ± 15° around
their longitudinal axis.
Important information
NOTICE
The housing of the sender and the receiver can become scratched if the screw heads
protrude when the Compact FlexFix brackets are mounted on the back.
This can be avoided by taking the following measure:
b
Use countersunk screws without washer.
NOTICE
The AR60 optional laser alignment aid can be used from a protective field height of
250 mm.
MOUNTING
5
8027557/2022-11-11 | SICK
O P E R A T I N G I N S T R U C T I O N S | senSe2
37
Subject to change without notice