88
O P E R A T I N G I N S T R U C T I O N S | safeRS3
8027489/2022-03-01 | SICK
Subject to change without notice
8 MAINTENANCE AND TROUBLESHOOTING
8.3.3
Factory reset
Every time a factory reset is required, the event is logged.
Format:
Factory reset
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL Factory reset
8.3.4
Stop signal
If configured, every change of the Stop Signal is logged as ACTIVATION or
DEACTIVATION.
Format:
Stop signal ACTIVATION/DEACTIVATION
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL Stop signal ACTIVATION
8.3.5
Restart signal
If configured, every time the system is waiting for the restart signal or the restart signal
is received, the event is logged as WAITING or RECEIVED.
Format:
Restart signal WAITING/RECEIVED
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL Restart signal RECEIVED
8.3.6
Detection access
Every time motion is detected, a detection access is logged with additional parameters
depending on the selected verbosity level: the protective field number, the sensor which
detected the motion, the detection distance (in mm) and the detection angle (°) (see
Verbosity level for detection access and exit events on page 86
).
Format:
Detection access (field #n, distance mm/azimuth°)
Example:
20 2020/11/18 16:47:25 [INFO] SENSOR #1 Detection access (field #1, 1200 mm/30°)
8.3.7
Detection exit
After at least one detection access event, a detection exit event related to the same
field is logged when the detection signal returns to its default no-motion status.