84
O P E R A T I N G I N S T R U C T I O N S | safeRS3
8027489/2022-03-01 | SICK
Subject to change without notice
8 MAINTENANCE AND TROUBLESHOOTING
8.2.5
Timestamp (seconds counter from the latest boot)
An indication of the instant when the event occurred is provided as relative time from
the latest boot, in seconds.
Example: 92
Meaning: the event occurred 92 seconds after the latest boot
8.2.6
Timestamp (absolute/relative value)
An indication of the instant when the event occurred is provided.
l
After a new system configuration, it is provided as absolute time.
Format:
YYYY/MM/DD hh:mm:ss
Example: 2020/06/05 23:53:44
l
After a reboot of the device, it is provided as relative time from the latest boot.
Format:
Rel. x d hh:mm:ss
Example: Rel. 0 d 00:01:32
Note
: when a new system configuration is performed, even the older timestamps are
updated in absolute time format.
Note
: during system configuration, the control is receiving the local time of the machine
where the software is running.
8.2.7
Event description
A complete description of the event is reported. Whenever possible, depending on the
event, additional parameters are reported.
In case of a diagnostic event, an internal error code is also added, useful for the
purpose of debug. If the diagnostic event disappears, the label “(Disappearing)” is
reported as an additional parameter.
Examples
Detection access (field #3, 1300 mm/40°)
System configuration #15
CAN ERROR (Code: 0x0010) COMMUNICATION LOST
CAN ERROR (disappearing)