9.5.2
Muting (with/without pulse)
Without pulse
With pulse
Part
Description
Diff
Less than 100 ms. If the value is greater than 100 ms, the diagnostic
alarm starts and the system deactivates the safety outputs.
Muting signal
(group
n) CH 1
Muting signal
(group
n) CH 2
Interchangeable channel.
Muting status
l
Without pulse: enabled as long as both channels are at a high logic
level (1), and deactivated when both channels go to low logic level (0).
l
With pulse: enabled as long as both the input signals follow the
configured muting parameters (pulse width, period and phase shift).
Dt
Activation/deactivation delay. Without pulse less than 50 ms, with pulse
less than three times the period.
9 TECHNICAL REFERENCES
8027489/2022-03-01 | SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | safeRS3
115